Literature DB >> 15734328

Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing electrode diameters.

Roger Guevremont1, Randy Purves.   

Abstract

High-field asymmetric waveform ion mobility spectrometry (FAIMS) separates ions at atmospheric pressure and room temperature based on the difference of the mobility of ions in strong electric fields and weak electric fields. This field-dependent mobility of an ion is reflected in the compensation voltage (CV) at which the ion is transmitted through FAIMS, at a given asymmetric waveform dispersion voltage (DV). Experimental CV, relative peak ion intensity, and peak width data were compared for three FAIMS prototypes with concentric cylindrical electrodes having inner/outer electrode radii of: (1) 0.4/0.6 cm, (2) 0.8/1.0 cm, and (3) 1.2/1.4 cm. The annular analyzer space was 0.2 cm wide in each case. A finite-difference numerical computation method is described for evaluation of peak shapes and widths in a CV spectrum collected using cylindrical geometry FAIMS devices. Simulation of the radial distribution of the ion density in the FAIMS analyzer is based upon calculation of diffusion, electric fields, and the electric fields introduced by coulombic ion-ion repulsion. Excellent agreement between experimental and calculated peak shapes were obtained for electrodes of wide diameter and for ions transmitted at low CV.

Year:  2005        PMID: 15734328     DOI: 10.1016/j.jasms.2004.11.013

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  14 in total

1.  Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS.

Authors:  R Guevremont; D A Barnett; R W Purves; J Vandermey
Journal:  Anal Chem       Date:  2000-10-01       Impact factor: 6.986

2.  Atmospheric pressure ion trapping in a tandem FAIMS-FAIMS coupled to a TOFMS: studies with electrospray generated gramicidin S ions.

Authors:  R Guevremont; L Ding; B Ells; D A Barnett; R W Purves
Journal:  J Am Soc Mass Spectrom       Date:  2001-12       Impact factor: 3.109

3.  Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas.

Authors:  G A Eiceman; E V Krylov; N S Krylova; E G Nazarov; R A Miller
Journal:  Anal Chem       Date:  2004-09-01       Impact factor: 6.986

4.  Modeling the resolution and sensitivity of FAIMS analyses.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

5.  Optimization of the design and operation of FAIMS analyzers.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-01       Impact factor: 3.109

6.  Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2004-12-15       Impact factor: 6.986

7.  Quantitation of morphine and codeine in human urine using high-filed asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometric detection.

Authors:  M A McCooeye; B Ells; D A Barnett; R W Purves; R Guevremont
Journal:  J Anal Toxicol       Date:  2001-03       Impact factor: 3.367

8.  Separation of o-, m- and p-phthalic acids by high-field asymmetric waveform ion mobility spectrometry (FAIMS) using mixed carrier gases

Authors: 
Journal:  J Mass Spectrom       Date:  2000-08       Impact factor: 1.982

9.  Gas-phase conformers of the [M + 2H](2+) ion of bradykinin investigated by combining high-field asymmetric waveform ion mobility spectrometry, hydrogen/deuterium exchange, and energy-loss measurements.

Authors:  R W Purves; D A Barnett; B Ells; R Guevremont
Journal:  Rapid Commun Mass Spectrom       Date:  2001       Impact factor: 2.419

10.  Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry.

Authors:  D A Barnett; B Ells; R Guevremont; R W Purves; L A Viehland
Journal:  J Am Soc Mass Spectrom       Date:  2000-12       Impact factor: 3.109

View more
  18 in total

1.  A high voltage asymmetric waveform generator for FAIMS.

Authors:  Jesse D Canterbury; James Gladden; Lon Buck; Roy Olund; Michael J MacCoss
Journal:  J Am Soc Mass Spectrom       Date:  2010-02-18       Impact factor: 3.109

2.  Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Authors:  Keqi Tang; Fumin Li; Alexandre A Shvartsburg; Eric F Strittmatter; Richard D Smith
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

3.  Compensation voltage (CV) peak shapes using a domed FAIMS with the inner electrode translated to various longitudinal positions.

Authors:  Roger Guevremont; Govindanunny Thekkadath; Christopher K Hilton
Journal:  J Am Soc Mass Spectrom       Date:  2005-04-15       Impact factor: 3.109

4.  High-resolution field asymmetric waveform ion mobility spectrometry using new planar geometry analyzers.

Authors:  Alexandre A Shvartsburg; Fumin Li; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

5.  Characterization of a temperature-controlled FAIMS system.

Authors:  David A Barnett; Michael Belford; Jean-Jacques Dunyach; Randy W Purves
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-22       Impact factor: 3.109

6.  Peak deconvolution in high-field asymmetric waveform ion mobility spectrometry (FAIMS) to characterize macromolecular conformations.

Authors:  Errol W Robinson; Rachel E Sellon; Evan R Williams
Journal:  Int J Mass Spectrom       Date:  2007-01-01       Impact factor: 1.986

7.  Ion peak narrowing by applying additional AC voltage (ripple voltage) to FAIMS extractor electrode.

Authors:  Viktor V Pervukhin; Dmitriy G Sheven
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-12       Impact factor: 3.109

8.  Optimization of a New Aerodynamic Cylindrical FAIMS Device for Small Molecule Analysis.

Authors:  Randy W Purves; Satendra Prasad; Michael Belford; Albert Vandenberg; Jean-Jacques Dunyach
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-17       Impact factor: 3.109

9.  Overtone mobility spectrometry: part 2. Theoretical considerations of resolving power.

Authors:  Stephen J Valentine; Sarah T Stokes; Ruwan T Kurulugama; Fabiane M Nachtigall; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2009-01-08       Impact factor: 3.109

10.  Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics.

Authors:  Jesse D Canterbury; Xianhua Yi; Michael R Hoopmann; Michael J MacCoss
Journal:  Anal Chem       Date:  2008-08-12       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.