Ion peak narrowing by applying additional AC voltage (ripple voltage) to FAIMS extractor electrode.

Viktor V Pervukhin1, Dmitriy G Sheven.   

Abstract

The use of a non-uniform electric field in a high-field asymmetric waveform ion mobility spectrometry (FAIMS) analyzer increases sensitivity but decreases resolution. The application of an additional AC voltage to the extractor electrode ("ripple" voltage, U(ripple)) can overcome this effect, which decreases the FAIMS peak width. In this approach, the diffusion ion loss remains minimal in the non-uniform electric field in the cylindrical part of the device, and all ion losses under U(ripple) occur in a short portion of their path. Application of the ripple voltage to the extractor electrode is twice as efficient as the applying of U(ripple) along the total length of the device. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

Year:  2009        PMID: 19819165     DOI: 10.1016/j.jasms.2009.09.001

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  6 in total

1.  Atmospheric pressure ion trapping in a tandem FAIMS-FAIMS coupled to a TOFMS: studies with electrospray generated gramicidin S ions.

Authors:  R Guevremont; L Ding; B Ells; D A Barnett; R W Purves
Journal:  J Am Soc Mass Spectrom       Date:  2001-12       Impact factor: 3.109

2.  Fast quantitative characterisation of differential mobility responses.

Authors:  Catherine A Veasey; C L P Thomas
Journal:  Analyst       Date:  2004-01-20       Impact factor: 4.616

3.  Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing electrode diameters.

Authors:  Roger Guevremont; Randy Purves
Journal:  J Am Soc Mass Spectrom       Date:  2005-01-19       Impact factor: 3.109

Review 4.  High-field asymmetric waveform ion mobility spectrometry: a new tool for mass spectrometry.

Authors:  Roger Guevremont
Journal:  J Chromatogr A       Date:  2004-11-26       Impact factor: 4.759

5.  Compensation voltage (CV) peak shapes using a domed FAIMS with the inner electrode translated to various longitudinal positions.

Authors:  Roger Guevremont; Govindanunny Thekkadath; Christopher K Hilton
Journal:  J Am Soc Mass Spectrom       Date:  2005-04-15       Impact factor: 3.109

6.  FAIMS operation for realistic gas flow profile and asymmetric waveforms including electronic noise and ripple.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-09       Impact factor: 3.109

  6 in total
  1 in total

1.  A high voltage asymmetric waveform generator for FAIMS.

Authors:  Jesse D Canterbury; James Gladden; Lon Buck; Roy Olund; Michael J MacCoss
Journal:  J Am Soc Mass Spectrom       Date:  2010-02-18       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.