Literature DB >> 10972997

Separation of o-, m- and p-phthalic acids by high-field asymmetric waveform ion mobility spectrometry (FAIMS) using mixed carrier gases

.   

Abstract

Baseline separation of the three isomers of phthalic acid was achieved in a mixed gas system containing a 95 : 5 mixture of N(2) and CO(2), even though the acids could not be distinguished by high-field asymmetric waveform ion mobility spectrometry (FAIMS) when either pure N(2) or pure CO(2) was used as the carrier gas. Pseudomolecular anions of o-, m- and p-phthalic acids were generated by electrospray ionization and detected, following separation by FAIMS, using a quadrupole mass spectrometer. Addition of small amounts of CO(2) to an N(2) carrier gas also caused the compensation voltages to increase by as much as 12 V, accompanied by 2-7-fold improvements in the measured ion current and dramatic reductions in both adduct ion formation and parent ion fragmentation. Copyright 2000 John Wiley & Sons, Ltd.

Entities:  

Year:  2000        PMID: 10972997     DOI: 10.1002/1096-9888(200008)35:8<976::AID-JMS25>3.0.CO;2-Q

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  17 in total

1.  Elongated conformers of charge states +11 to +15 of bovine ubiquitin studied using ESI-FAIMS-MS.

Authors:  R W Purves; D A Barnett; B Ells; R Guevremont
Journal:  J Am Soc Mass Spectrom       Date:  2001-08       Impact factor: 3.109

2.  Application of ESI-FAIMS-MS to the analysis of tryptic peptides.

Authors:  David A Barnett; Barbara Ells; Roger Guevremont; Randy W Purves
Journal:  J Am Soc Mass Spectrom       Date:  2002-11       Impact factor: 3.109

3.  Modeling the resolution and sensitivity of FAIMS analyses.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

4.  Optimization of the design and operation of FAIMS analyzers.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-01       Impact factor: 3.109

5.  Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing electrode diameters.

Authors:  Roger Guevremont; Randy Purves
Journal:  J Am Soc Mass Spectrom       Date:  2005-01-19       Impact factor: 3.109

6.  Compensation voltage (CV) peak shapes using a domed FAIMS with the inner electrode translated to various longitudinal positions.

Authors:  Roger Guevremont; Govindanunny Thekkadath; Christopher K Hilton
Journal:  J Am Soc Mass Spectrom       Date:  2005-04-15       Impact factor: 3.109

7.  High-resolution field asymmetric waveform ion mobility spectrometry using new planar geometry analyzers.

Authors:  Alexandre A Shvartsburg; Fumin Li; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

8.  Peak deconvolution in high-field asymmetric waveform ion mobility spectrometry (FAIMS) to characterize macromolecular conformations.

Authors:  Errol W Robinson; Rachel E Sellon; Evan R Williams
Journal:  Int J Mass Spectrom       Date:  2007-01-01       Impact factor: 1.986

9.  Differential ion mobility separations in up to 100% helium using microchips.

Authors:  Alexandre A Shvartsburg; Yehia M Ibrahim; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-09       Impact factor: 3.109

10.  Overtone mobility spectrometry: part 2. Theoretical considerations of resolving power.

Authors:  Stephen J Valentine; Sarah T Stokes; Ruwan T Kurulugama; Fabiane M Nachtigall; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2009-01-08       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.