Literature DB >> 15715428

Preliminary evaluation of implantable MOSFET radiation dosimeters.

A S Beddar1, M Salehpour, T M Briere, H Hamidian, M T Gillin.   

Abstract

In this paper, we report on measurements performed on a new prototype implantable radiation detector that uses metal-oxide semiconductor field effect transistors (MOSFETs) designed for in vivo dosimetry. The dosimeters, which are encapsulated in hermetically sealed glass cylinders, are used in an unbiased mode during irradiation, unlike other MOSFET detectors previously used in radiotherapy applications. They are powered by radio frequency telemetry for dose measurements, obviating the need for a power supply within each capsule. We have studied the dosimetric characteristics of these MOSFET detectors in vitro under irradiation from a 60Co source. The detectors show a dose reproducibility generally within 5% or better, with the main sources of error being temperature fluctuations occurring between the pre- and post-irradiation measurements as well as detector orientation. A better temperature-controlled environment leads to a reproducibility within 2%. Our preliminary in vitro results show clearly that true non-invasive in vivo dosimetry measurements are feasible and can be performed remotely using telemetric technology.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15715428     DOI: 10.1088/0031-9155/50/1/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  An analysis of an implantable dosimeter system for external beam therapy.

Authors:  Robert D Black; Charles W Scarantino; Gregory G Mann; Mitchell S Anscher; Robert D Ornitz; Benjamin E Nelms
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-09-01       Impact factor: 7.038

2.  The observed variance between predicted and measured radiation dose in breast and prostate patients utilizing an in vivo dosimeter.

Authors:  Charles W Scarantino; Bradley R Prestidge; Mitchel S Anscher; Carolyn R Ferree; William T Kearns; Robert D Black; Natasha G Bolick; Gloria P Beyer
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-10-01       Impact factor: 7.038

3.  Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

Authors:  Zhong Su; Lisha Zhang; V Ramakrishnan; Michael Hagan; Mitchell Anscher
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

4.  Uncertainties encountered in implementation of adaptive planning with in vivo dosimeters.

Authors:  M T Studenski; S J Gardner; R B Den
Journal:  Radiol Phys Technol       Date:  2014-09-19

5.  Radiation-induced lung injury is mitigated by blockade of gastrin-releasing peptide.

Authors:  Shutang Zhou; Esther Nissao; Isabel L Jackson; Wei Leong; Lindsay Dancy; Frank Cuttitta; Zeljko Vujaskovic; Mary E Sunday
Journal:  Am J Pathol       Date:  2013-02-08       Impact factor: 4.307

6.  Temporal expression of hypoxia-regulated genes is associated with early changes in redox status in irradiated lung.

Authors:  Isabel L Jackson; Xiuwu Zhang; Caroline Hadley; Zahid N Rabbani; Yu Zhang; Sam Marks; Zeljko Vujaskovic
Journal:  Free Radic Biol Med       Date:  2012-04-25       Impact factor: 7.376

7.  Is the in vivo dosimetry with the OneDosePlusTM system able to detect intra-fraction motion? A retrospective analysis of in vivo data from breast and prostate patients.

Authors:  Maria Daniela Falco; Marco D'Andrea; Alessia Lo Bosco; Mauro Rebuzzi; Elisabetta Ponti; Barbara Tolu; Grazia Tortorelli; Rosaria Barbarino; Luana Di Murro; Riccardo Santoni
Journal:  Radiat Oncol       Date:  2012-06-20       Impact factor: 3.481

8.  Investigation into the use of a MOSFET dosimeter as an implantable fiducial marker.

Authors:  Stephen F Kry; Michael Price; Zhonglu Wang; Firas Mourtada; Mohammad Salehpour
Journal:  J Appl Clin Med Phys       Date:  2009-01-27       Impact factor: 2.102

9.  Commissioning and implementation of an implantable dosimeter for radiation therapy.

Authors:  Ivan Buzurovic; Timothy N Showalter; Matthew T Studenski; Robert B Den; Adam P Dicker; Junsheng Cao; Ying Xiao; Yan Yu; Amy Harrison
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

10.  Patient dosimetry for total body irradiation using single-use MOSFET detectors.

Authors:  Tina Marie Briere; Ramesh Tailor; Naresh Tolani; Karl Prado; Richard Lane; Shiao Woo; Chul Ha; Michael T Gillin; A Sam Beddar
Journal:  J Appl Clin Med Phys       Date:  2008-11-03       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.