Literature DB >> 24390162

OPTIMAL MULTI-CHANNEL TIME-SEQUENTIAL ACQUISITION IN DYNAMIC MRI WITH PARALLEL COILS.

Behzad Sharif1, Yoram Bresler1.   

Abstract

Magnetic resonance imaging with parallel coils is commonly used as a method to speed up the acquisition by exploiting spatial encoding. Another, distinct acceleration method is spatio-temporal modeling with adaptive acquisition, which has been previously proposed for dynamic cardiac MRI with a single coil. We propose an optimal acquisition scheme for parallel dynamic MRI combining the two methods. It provides accelerations up to the product of the individual accelerations. The proposed scheme produces an artifact-free cine of the dynamic object, with high spatial and temporal resolution. Simulations demonstrate the method for cases where neither parallel imaging nor adaptive acquisition alone is feasible.

Entities:  

Year:  2006        PMID: 24390162      PMCID: PMC3879138          DOI: 10.1109/ISBI.2006.1624848

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Biomed Imaging        ISSN: 1945-7928


  3 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Sensitivity encoding as a means of enhancing the SNR efficiency in steady-state MRI.

Authors:  Markus Weiger; Peter Boesiger; Paul R Hilfiker; Dominik Weishaupt; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

  3 in total
  4 in total

1.  Improved time series reconstruction for dynamic magnetic resonance imaging.

Authors:  Uygar Sümbül; Juan M Santos; John M Pauly
Journal:  IEEE Trans Med Imaging       Date:  2009-01-13       Impact factor: 10.048

2.  ADAPTIVE REAL-TIME CARDIAC MRI USING PARADISE: VALIDATION BY THE PHYSIOLOGICALLY IMPROVED NCAT PHANTOM.

Authors:  Behzad Sharif; Yoram Bresler
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2007

3.  AFFINE-CORRECTED PARADISE: FREE-BREATHING PATIENT-ADAPTIVE CARDIAC MRI WITH SENSITIVITY ENCODING.

Authors:  Behzad Sharif; Yoram Bresler
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2007

4.  Patient-adaptive reconstruction and acquisition in dynamic imaging with sensitivity encoding (PARADISE).

Authors:  Behzad Sharif; J Andrew Derbyshire; Anthony Z Faranesh; Yoram Bresler
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.