Literature DB >> 26000083

Biomechanical comparison of four mandibular angle fracture fixation techniques.

Jose Luis Muñante-Cardenas1, Luis Augusto Passeri1.   

Abstract

The aim of this study was to make a comparison of the biomechanical behavior of four different internal fixation systems for mandibular angle fractures. A total of 40 polyurethane mandible replicas were employed with different fixation methods: group 1SP, one 2.0-mm four-hole miniplate; group 2PPL, two 2.0-mm four-hole parallel miniplates; group 3DP, one 3D 2.0-mm four-hole miniplate; and group 3DPP, one 3D 2.0-mm eight-hole miniplate. Each group was subjected to incisal or homolateral molar region loading. The load resistance values were measured at load application causing tip displacement of 1, 3, and 5 mm, and at the time at which the system achieves its maximum strength (MS). Means and standard deviations were compared among groups using analysis of variance and the Tukey test. Group 2PPL showed higher strength for all the displacements. For incisal loading, no statistically significant differences were found between groups 1SP, 3DP, and 3DPP. For molar loading, group 1SP and 3DPP showed statistically significant differences. For MS testing, group 1SP and 2PPL showed statistically significant differences in incisal loading; group 1SP and 3DP showed no statistically significant differences; and group 3DPP showed lower values of strength. Two parallel miniplates provide the most favorable mechanical behavior under the conditions tested.

Entities:  

Keywords:  3D plates; compressive strength; mandibular angle fractures; material resistance

Year:  2014        PMID: 26000083      PMCID: PMC4428728          DOI: 10.1055/s-0034-1393737

Source DB:  PubMed          Journal:  Craniomaxillofac Trauma Reconstr        ISSN: 1943-3875


  30 in total

1.  Epidemiological analysis of maxillofacial fractures in Brazil: a 5-year prospective study.

Authors:  Bernardo Ferreira Brasileiro; Luis Augusto Passeri
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-03-22

2.  Complications of nonrigid fixation of mandibular angle fractures.

Authors:  L A Passeri; E Ellis; D P Sinn
Journal:  J Oral Maxillofac Surg       Date:  1993-04       Impact factor: 1.895

3.  One- or two-plate fixation of mandibular angle fractures?

Authors:  H P Schierle; R Schmelzeisen; B Rahn; C Pytlik
Journal:  J Craniomaxillofac Surg       Date:  1997-06       Impact factor: 2.078

4.  Epidemiology of maxillofacial injuries at trauma hospitals in Ontario, Canada, between 1992 and 1997.

Authors:  N J Hogg; T C Stewart; J E Armstrong; M J Girotti
Journal:  J Trauma       Date:  2000-09

5.  Mechanical evaluation of different techniques for symphysis fracture fixation--an in vitro polyurethane mandible study.

Authors:  Thalita Regina Vieira e Oliveira; Luis Augusto Passeri
Journal:  J Oral Maxillofac Surg       Date:  2011-03-12       Impact factor: 1.895

6.  Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle.

Authors:  Juergen Zix; Olivier Lieger; Tateyuki Iizuka
Journal:  J Oral Maxillofac Surg       Date:  2007-09       Impact factor: 1.895

7.  Improvement of maximum occlusal forces after orthognathic surgery.

Authors:  G S Throckmorton; P H Buschang; E Ellis
Journal:  J Oral Maxillofac Surg       Date:  1996-09       Impact factor: 1.895

8.  Five-year retrospective study of mandibular fractures in Freiburg, Germany: incidence, etiology, treatment, and complications.

Authors:  Kai-Hendrik Bormann; Sarah Wild; Nils-Claudius Gellrich; Horst Kokemüller; Constantin Stühmer; Rainer Schmelzeisen; Ralf Schön
Journal:  J Oral Maxillofac Surg       Date:  2009-06       Impact factor: 1.895

9.  Biomechanical evaluation of plating techniques for fixing mandibular angle fractures: the introduction of a new 3D plate approach.

Authors:  Evagelos F Kalfarentzos; Despoina Deligianni; Georgios Mitros; Minos Tyllianakis
Journal:  Oral Maxillofac Surg       Date:  2009-09

10.  Stability testing of a two miniplate fixation technique for mandibular angle fractures. An in vitro study.

Authors:  B H Choi; J H Yoo; K N Kim; H S Kang
Journal:  J Craniomaxillofac Surg       Date:  1995-04       Impact factor: 2.078

View more
  1 in total

1.  Integrity of a Single Superior Border Plate Repair in Mandibular Angle Fracture: A Novel Cadaveric Human Mandible Model.

Authors:  Somsak Sittitavornwong; Douglas Denson; David Ashley; David Cruz Walma; Sarah Potter; Jonathan Freind
Journal:  J Oral Maxillofac Surg       Date:  2018-08-06       Impact factor: 1.895

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.