Instrumented socket inserts for sensing interaction at the limb-socket interface.

Eric C Swanson1, Jake B McLean2, Katheryn J Allyn3, Christian B Redd4, Joan E Sanders5.   

Abstract

The objective of this research was to investigate a strategy for designing and fabricating computer-manufactured socket inserts that were embedded with sensors for field monitoring of limb-socket interactions of prosthetic users. An instrumented insert was fabricated for a single trans-tibial prosthesis user that contained three sensor types (proximity sensor, force sensing resistor, and inductive sensor), and the system was evaluated through a sequence of laboratory clinical tests and two days of field use. During in-lab tests 3 proximity sensors accurately distinguish between don and doff states; 3 of 4 force sensing resistors measured gradual pressure increases as weight-bearing increased; and the inductive sensor indicated that as prosthetic socks were added the limb moved farther out of the socket and pistoning amplitude decreased. Multiple sensor types were necessary in analysis of field collected data to interpret how sock changes affected limb-socket interactions. Instrumented socket inserts, with sensors selected to match clinical questions of interest, have the potential to provide important insights to improve patient care.
Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CAD/CAM; Interfacial sensors; Lower-limb amputee; Prosthetic socket; Residual limb; Socket fit

Mesh:

Year:  2017        PMID: 29229405      PMCID: PMC5748260          DOI: 10.1016/j.medengphy.2017.11.006

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  14 in total

1.  Standing interface stresses as a predictor of walking interface stresses in the trans-tibial prosthesis.

Authors:  S G Zachariah; J E Sanders
Journal:  Prosthet Orthot Int       Date:  2001-04       Impact factor: 1.895

2.  How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?

Authors:  Joan E Sanders; Daniel S Harrison; Katheryn J Allyn; Timothy R Myers; Marcia A Ciol; Elaine C Tsai
Journal:  J Rehabil Res Dev       Date:  2012

3.  Comparison of interface pressures with pin and suction suspension systems.

Authors:  Tracy L Beil; Glenn M Street
Journal:  J Rehabil Res Dev       Date:  2004 Nov-Dec

4.  The effect of biomechanical variables on force sensitive resistor error: Implications for calibration and improved accuracy.

Authors:  Jonathon S Schofield; Katherine R Evans; Jacqueline S Hebert; Paul D Marasco; Jason P Carey
Journal:  J Biomech       Date:  2016-02-09       Impact factor: 2.712

5.  Effects of alignment changes on stance phase pressures and shear stresses on transtibial amputees: measurements from 13 transducer sites.

Authors:  J E Sanders; D M Bell; R M Okumura; A J Dralle
Journal:  IEEE Trans Rehabil Eng       Date:  1998-03

6.  Does temporary socket removal affect residual limb fluid volume of trans-tibial amputees?

Authors:  Joan E Sanders; Tyler L Hartley; Reid H Phillips; Marcia A Ciol; Brian J Hafner; Katheryn J Allyn; Dan S Harrison
Journal:  Prosthet Orthot Int       Date:  2015-02-20       Impact factor: 1.895

Review 7.  Considerations for development of sensing and monitoring tools to facilitate treatment and care of persons with lower-limb loss: a review.

Authors:  Brian J Hafner; Joan E Sanders
Journal:  J Rehabil Res Dev       Date:  2014

8.  Technical note: Computer-manufactured inserts for prosthetic sockets.

Authors:  Joan E Sanders; Jake B McLean; John C Cagle; David W Gardner; Katheryn J Allyn
Journal:  Med Eng Phys       Date:  2016-05-17       Impact factor: 2.242

9.  Amputee socks: thickness of multiple socks.

Authors:  John C Cagle; Alan J Yu; Marcia A Ciol; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2013-11-15       Impact factor: 1.895

10.  Detection of Prosthetic Knee Movement Phases via In-Socket Sensors: A Feasibility Study.

Authors:  Amr M El-Sayed; Nur Azah Hamzaid; Kenneth Y S Tan; Noor Azuan Abu Osman
Journal:  ScientificWorldJournal       Date:  2015-04-05
View more
  12 in total

1.  Power Wheelchair Footplate Pressure and Positioning Sensor.

Authors:  Steve J A Majerus; Joseph Lerchbacker; Daniel Barbaro; Steven J Mitchell; Kath M Bogie; M Kristi Henzel
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

2.  A Novel Method for Assessing Prosthesis Use and Accommodation Practices of People with Transtibial Amputation.

Authors:  Joan E Sanders; Christian B Redd; Brian G Larsen; Andrew C Vamos; Jacob T Brzostowski; Brian J Hafner; Katheryn J Allyn; Katrina Henrikson; Jake B McLean; Paul Hinrichs
Journal:  J Prosthet Orthot       Date:  2018-10

3.  Modeling the mechanics of elevated vacuum systems in prosthetic sockets.

Authors:  Robert T Youngblood; Brian J Hafner; Joseph M Czerniecki; Jacob T Brzostowski; Katheryn J Allyn; Joan E Sanders
Journal:  Med Eng Phys       Date:  2020-07-28       Impact factor: 2.242

4.  Prosthetists' perceptions of information obtained from a lower limb prosthesis monitoring system: a pilot study.

Authors:  Geoffrey S Balkman; Andrew C Vamos; Joan E Sanders; Brian G Larsen; Brian J Hafner
Journal:  J Prosthet Orthot       Date:  2019-04

5.  Textile-based Pressure Sensors for Monitoring Prosthetic-Socket Interfaces.

Authors:  Jordan Tabor; Talha Agcayazi; Aaron Fleming; Brendan Thompson; Ashish Kapoor; Ming Liu; Michael Lee; He Helen Huang; Alper Bozkurt; Tushar Ghosh
Journal:  IEEE Sens J       Date:  2021-01-21       Impact factor: 3.301

6.  An Inductive Sensing System to Measure In-Socket Residual Limb Displacements for People Using Lower-Limb Prostheses.

Authors:  Katrina M Henrikson; Ethan J Weathersby; Brian G Larsen; John C Cagle; Jake B McLean; Joan E Sanders
Journal:  Sensors (Basel)       Date:  2018-11-09       Impact factor: 3.576

7.  Development of a magnetic composite material for measurement of residual limb displacements in prosthetic sockets.

Authors:  Ethan J Weathersby; John C Cagle; Brian G Larsen; Katrina M Henrikson; Joan E Sanders
Journal:  J Rehabil Assist Technol Eng       Date:  2018-04-03

Review 8.  New technologies applied to canine limb prostheses: A review.

Authors:  Paul G Arauz; Patricio Chiriboga; María-Gabriela García; Imin Kao; Eduardo A Díaz
Journal:  Vet World       Date:  2021-10-28

9.  Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics.

Authors:  Ethan J Weathersby; Clement J Gurrey; Jake B McLean; Benjamin N Sanders; Brian G Larsen; Ryan Carter; Joseph L Garbini; Joan E Sanders
Journal:  Sensors (Basel)       Date:  2019-09-19       Impact factor: 3.576

10.  Changes in Tissue Composition and Load Response After Transtibial Amputation Indicate Biomechanical Adaptation.

Authors:  J L Bramley; P R Worsley; D L Bader; C Everitt; A Darekar; L King; A S Dickinson
Journal:  Ann Biomed Eng       Date:  2021-09-27       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.