Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement.

Giordano Tasca1, Federico Brunelli, Marco Cirillo, Margherita DallaTomba, Zen Mhagna, Giovanni Troise, Eugenio Quaini.   

Abstract

BACKGROUND: Valve prosthesis-patient mismatch is a frequent problem in patients undergoing aortic valve replacement and its main hemodynamic consequence is to generate high transvalvular gradients through normally functioning prosthetic valves. The persistence of high gradients may hinder or delay the regression of left ventricular hypertrophy after aortic valve replacement.
METHODS: The aim of the study was to determine the impact of prosthesis-patient mismatch on the postoperative regression of left ventricular mass. Left ventricular mass was measured by Doppler echocardiography in 109 patients undergoing aortic valve replacement with a single type of bioprosthesis (Carpentier-Edwards Perimount) for pure aortic stenosis. Prosthesis-patient mismatch was defined as a projected indexed effective orifice area less than 0.90 cm2/m2. On this basis, 58/109 (53.2%) patients had prosthesis-patient mismatch.
RESULTS: There was a good correlation (r = 0.61, p < 0.001) between the postoperative mean transprosthetic gradient and the projected indexed effective orifice area. The absolute and relative left ventricular mass regression was significantly (p = 0.002 and p = 0.01, respectively) lower in patients with prosthesis-patient mismatch (-48 +/- 47 g, -17% +/- 16%) compared to those with no prosthesis-patient mismatch (-77 +/- 49 g, -24% +/- 14%). In multivariate analysis, a larger projected indexed effective orifice area, female gender and a higher preoperative left ventricular mass are independent predictors of greater left ventricular mass regression.
CONCLUSIONS: This study shows that in patients with pure aortic stenosis prosthesis-patient mismatch is associated with lesser regression of left ventricular hypertrophy after aortic valve replacement. These findings may have important clinical implications given that prosthesis-patient mismatch is frequent in these patients.

Entities:  

Mesh:

Year:  2005        PMID: 15680824     DOI: 10.1016/j.athoracsur.2004.04.042

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  28 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

3.  Patterns of left ventricular remodeling in aortic stenosis: therapeutic implications.

Authors:  Sammy Elmariah
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-07

4.  Left ventricular mass regression in patients without patient-prosthesis mismatch after aortic valve replacement for aortic stenosis.

Authors:  Kohei Hachiro; Takeshi Kinoshita; Tohru Asai; Tomoaki Suzuki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-08-14

Review 5.  The role of echocardiography in transcatheter aortic valve implantation.

Authors:  Toshinari Onishi; Kaoruko Sengoku; Yasuhiro Ichibori; Isamu Mizote; Koichi Maeda; Toru Kuratani; Yoshiki Sawa; Yasushi Sakata
Journal:  Cardiovasc Diagn Ther       Date:  2018-02

Review 6.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

7.  Aortic valve replacement for aortic stenosis in the elderly: influence of prosthesis-patient mismatch on late survival and left ventricular mass regression.

Authors:  Yasuyuki Kato; Yasushi Tsutsumi; Takahiro Kawai; Tomoyuki Goto; Yosuke Takahashi; Hirokazu Ohashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-08-13

8.  Prosthetic valves in adult patients with congenital heart disease: Rationale and design of the Dutch PROSTAVA study.

Authors:  H G Freling; Y J van Slooten; J P van Melle; B J M Mulder; A P J van Dijk; H L Hillege; M C Post; G Tj Sieswerda; M R M Jongbloed; T P Willems; P G Pieper
Journal:  Neth Heart J       Date:  2012-10       Impact factor: 2.380

9.  Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography.

Authors:  Cristina da Silva; Anders Sahlen; Reidar Winter; Magnus Bäck; Andreas Rück; Magnus Settergren; Aristomenis Manouras; Kambiz Shahgaldi
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-08       Impact factor: 2.357

Review 10.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.