Literature DB >> 32930802

Determination of reproducibility of end-exhaled breath-holding in stereotactic body radiation therapy.

Motoharu Sasaki1, Hitoshi Ikushima1, Kanako Sakuragawa2, Michihiro Yokoishi2, Akira Tsuzuki3, Wataru Sugimoto4.   

Abstract

Methods to evaluate the positional reproducibility of breath-hold irradiation mostly require manual operation. The purpose of this study is to propose a method to determine the reproducibility of breath-hold irradiation of lung tumors between fractions using non-artificial methods. This study included 13 patients who underwent terminal exhaled breath-hold irradiation for primary and metastatic lung cancer. All subjects received a prescribed dose of 60 Gy/8 fractions. The contours of the gross tumor volume (GTV) were extracted by threshold processing using treatment-planning computed tomography (CT) and cone-beam CT (CBCT), which was done just before the beginning of the treatment. The method proposed in this study evaluates the dice similarity coefficient (DSC) and Hausdorff distance (HD) by comparing two volumes, the GTVCTS (GTV obtained from treatment-planning CT) and GTVCBCT (GTV obtained from CBCT). The reference contours for DSC and HD are represented by GTVCTS. The results demonstrated good visual agreement for cases with a DSC of ~0.7. However, apparent misalignment occurred when the DSC was <0.5. HD was >2 mm in 3 out of 13 cases, and when the DSC was ~0.7, the HD was ~1 mm. In addition, cases with greater HD also demonstrated more significant variability. It was found that the DSC and HD evaluation methods for the positional reproducibility of breath-hold irradiation proposed in this study are straightforward and can be performed without the involvement of humans. Our study is of extreme significance in the field of radiation studies.
© The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology.

Entities:  

Keywords:  Hausdorff distance; breath-hold irradiation; dice similarity coefficient; lung cancer

Year:  2020        PMID: 32930802      PMCID: PMC7674682          DOI: 10.1093/jrr/rraa079

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  21 in total

1.  Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: a feasibility study.

Authors:  D J Kim; B R Murray; R Halperin; W H Roa
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-01-01       Impact factor: 7.038

2.  Ultrasound quantitation of respiratory organ motion in the upper abdomen.

Authors:  S C Davies; A L Hill; R B Holmes; M Halliwell; P C Jackson
Journal:  Br J Radiol       Date:  1994-11       Impact factor: 3.039

3.  Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography.

Authors:  C S Ross; D H Hussey; E C Pennington; W Stanford; J F Doornbos
Journal:  Int J Radiat Oncol Biol Phys       Date:  1990-03       Impact factor: 7.038

4.  Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer.

Authors:  David Sarrut; Vlad Boldea; Myriam Ayadi; Jean-Noël Badel; Chantal Ginestet; Sébastien Clippe; Christian Carrie
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

5.  Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frame.

Authors:  Yasushi Nagata; Kenji Takayama; Yukinori Matsuo; Yoshiki Norihisa; Takashi Mizowaki; Takashi Sakamoto; Masato Sakamoto; Michihide Mitsumori; Keiko Shibuya; Norio Araki; Shinsuke Yano; Masahiro Hiraoka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-09-19       Impact factor: 7.038

6.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy.

Authors:  H Shirato; S Shimizu; T Kunieda; K Kitamura; M van Herk; K Kagei; T Nishioka; S Hashimoto; K Fujita; H Aoyama; K Tsuchiya; K Kudo; K Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-11-01       Impact factor: 7.038

7.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer.

Authors:  D Mah; J Hanley; K E Rosenzweig; E Yorke; L Braban; C C Ling; S A Leibel; G Mageras
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-11-01       Impact factor: 7.038

8.  Reproducibility of diaphragm position assessed with a voluntary breath-holding device.

Authors:  Shigeyuki Takamatsu; Tsuyoshi Takanaka; Tomoyasu Kumano; Eiichi Mizuno; Satoshi Shibata; Shizuko Ohashi; Yuichi Kurata; Shinichi Ueda; Naoki Hori; Saori Shouji; Kimiya Noto; Hironori Kojima; Osamu Matsui
Journal:  Jpn J Radiol       Date:  2013-03-23       Impact factor: 2.374

9.  Estimation of patient-specific imaging dose for real-time tumour monitoring in lung patients during respiratory-gated radiotherapy.

Authors:  Takehiro Shiinoki; Ryota Onizuka; Daisuke Kawahara; Tatsuhiko Suzuki; Yuki Yuasa; Koya Fujimoto; Takuya Uehara; Hideki Hanazawa; Keiko Shibuya
Journal:  Phys Med Biol       Date:  2018-03-21       Impact factor: 3.609

10.  Prospective Trial of Stereotactic Body Radiation Therapy for Both Operable and Inoperable T1N0M0 Non-Small Cell Lung Cancer: Japan Clinical Oncology Group Study JCOG0403.

Authors:  Yasushi Nagata; Masahiro Hiraoka; Taro Shibata; Hiroshi Onishi; Masaki Kokubo; Katsuyuki Karasawa; Yoshiyuki Shioyama; Rikiya Onimaru; Takuyo Kozuka; Etsuo Kunieda; Tsutomu Saito; Keiichi Nakagawa; Masato Hareyama; Yoshihiro Takai; Kazushige Hayakawa; Norio Mitsuhashi; Satoshi Ishikura
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-11-11       Impact factor: 7.038

View more
  1 in total

1.  Effect of dental metal artifact conversion volume on dose distribution in head-and-neck volumetric-modulated arc therapy.

Authors:  Kenta Kitagawa; Hitoshi Ikushima; Motoharu Sasaki; Shunsuke Furutani; Takashi Kawanaka; Akiko Kubo; Chisato Tonoiso; Takaharu Kudoh; Yosuke Kano; Akira Tsuzuki
Journal:  J Appl Clin Med Phys       Date:  2020-11-23       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.