Literature DB >> 15653709

Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit.

H L Tan1, M Pinder, R Parsons, B Roberts, P V van Heerden.   

Abstract

BACKGROUND: The USCOM ultrasonic cardiac output monitor (USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non-invasive device that determines cardiac output by continuous-wave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the thermodilution technique in intensive care patients who had just undergone cardiac surgery.
METHODS: We conducted a prospective study in the 18-bed intensive care unit of a 600-bed tertiary referral hospital. Twenty-four mechanically ventilated patients were studied immediately following cardiac surgery. We evaluated the USCOM monitor by comparing its output with paired measurements obtained by the standard thermodilution technique using a pulmonary artery catheter.
RESULTS: Forty paired measurements were obtained in 22 patients. We were unable to obtain an acceptable signal in the remaining two patients. Comparison of the two techniques showed a bias of 0.18 and limits of agreement of -1.43 to 1.78. The agreement may not be as good between techniques at higher cardiac output values.
CONCLUSIONS: The USCOM monitor has a place in intensive care monitoring. It is accurate, rapid, safe, well-tolerated, non-invasive and cost-effective. The learning curve for skill acquisition is very short. However, during the learning phase the USCOM monitor measurements are rather 'operator dependent'. Its suitability for use in high and low cardiac output states requires further validation.

Entities:  

Mesh:

Year:  2005        PMID: 15653709     DOI: 10.1093/bja/aei054

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  28 in total

Review 1.  [Assessment of systolic function in patients with poor echogenicity: echocardiographic methods].

Authors:  F Weidemann; D Liu; M Niemann; S Herrmann; H Hu; P D Gaudron; G Ertl; K Hu
Journal:  Herz       Date:  2013-08-15       Impact factor: 1.443

2.  Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Christina Doesch; Theano Papavassiliu; Stefan O Schoenberg; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  J Clin Monit Comput       Date:  2015-06-27       Impact factor: 2.502

3.  In vitro evaluation of an ultrasonic cardiac output monitoring (USCOM) device.

Authors:  Shaun D Gregory; Helena Cooney; Sara Diab; Chris Anstey; Ogilvie Thom; John F Fraser
Journal:  J Clin Monit Comput       Date:  2015-03-07       Impact factor: 2.502

Review 4.  [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

Authors:  G Pestel; K Fukui; M Higashi; I Schmidtmann; C Werner
Journal:  Anaesthesist       Date:  2018-06       Impact factor: 1.041

5.  A pilot assessment of the FloTrac cardiac output monitoring system.

Authors:  Helen Ingrid Opdam; Li Wan; Rinaldo Bellomo
Journal:  Intensive Care Med       Date:  2006-10-25       Impact factor: 17.440

6.  Cardiac index measurements by transcutaneous Doppler ultrasound and transthoracic echocardiography in adult and pediatric emergency patients.

Authors:  H Bryant Nguyen; Daryl P Banta; Gail Stewart; Tommy Kim; Ramesh Bansal; James Anholm; William A Wittlake; Stephen W Corbett
Journal:  J Clin Monit Comput       Date:  2010-06-20       Impact factor: 2.502

7.  Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry.

Authors:  Stephan Schubert; Thomas Schmitz; Markus Weiss; Nicole Nagdyman; Michael Huebler; Vladimir Alexi-Meskishvili; Felix Berger; Brigitte Stiller
Journal:  J Clin Monit Comput       Date:  2008-07-30       Impact factor: 2.502

8.  Cardiac output measurement in children: comparison of the Ultrasound Cardiac Output Monitor with thermodilution cardiac output measurement.

Authors:  Walter Knirsch; Oliver Kretschmar; Maren Tomaske; Kathrina Stutz; Nicole Nagdyman; Christian Balmer; Achim Schmitz; Dominique Béttex; Felix Berger; Urs Bauersfeld; Markus Weiss
Journal:  Intensive Care Med       Date:  2008-02-23       Impact factor: 17.440

9.  Validation of an Ultrasound Cardiac Output Monitor as a Bedside Tool for Pediatric Patients.

Authors:  Fernando Beltramo; Jondavid Menteer; Asma Razavi; Robinder G Khemani; Jacqueline Szmuszkovicz; Christopher J L Newth; Patrick A Ross
Journal:  Pediatr Cardiol       Date:  2015-09-12       Impact factor: 1.655

10.  Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study.

Authors:  Steven W Thiel; Marin H Kollef; Warren Isakow
Journal:  Crit Care       Date:  2009-07-08       Impact factor: 9.097

View more