Literature DB >> 15577475

Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

John J Callaghan1, Michael R O'Rourke, Devon D Goetz, David G Lewallen, Richard C Johnston, William N Capello.   

Abstract

Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

Entities:  

Mesh:

Year:  2004        PMID: 15577475     DOI: 10.1097/01.blo.0000150276.98701.95

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  15 in total

1.  The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years.

Authors:  Remi Philippot; Jean Philippe Camilleri; Bertrand Boyer; Philippe Adam; Frederic Farizon
Journal:  Int Orthop       Date:  2008-06-03       Impact factor: 3.075

2.  Are abductor muscle quality and previous revision surgery predictors of constrained liner failure in hip arthroplasty?

Authors:  Michael G Zywiel; Loi'y H Mustafa; Peter M Bonutti; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-20       Impact factor: 3.075

Review 3.  Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Authors:  Thomas D Brown; Jacob M Elkins; Douglas R Pedersen; John J Callaghan
Journal:  Iowa Orthop J       Date:  2014

4.  CORR Insights®: What Is the Survivorship of Revision Surgery Performed for the Chronically Dislocated THA?

Authors:  Denis Nam
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

5.  Instability after total hip arthroplasty.

Authors:  Brian C Werner; Thomas E Brown
Journal:  World J Orthop       Date:  2012-08-18

6.  Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series.

Authors:  D Saragaglia; S Ruatti; R Refaie
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-05-06

7.  Constrained liner in neurologic or cognitively impaired patients undergoing primary THA.

Authors:  Philippe Hernigou; Paolo Filippini; Charles-Henri Flouzat-Lachaniette; Sobrinho Uirassu Batista; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

Review 8.  Constrained components for the unstable hip following total hip arthroplasty: a literature review.

Authors:  J T Williams; P S Ragland; S Clarke
Journal:  Int Orthop       Date:  2006-08-23       Impact factor: 3.075

Review 9.  Dislocation following total hip replacement.

Authors:  Jens Dargel; Johannes Oppermann; Gert-Peter Brüggemann; Peer Eysel
Journal:  Dtsch Arztebl Int       Date:  2014-12-22       Impact factor: 5.594

10.  Dual mobility cemented cups have low dislocation rates in THA revisions.

Authors:  Frantz L Langlais; Mickaël Ropars; François Gaucher; Thierry Musset; Olivier Chaix
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

View more