Literature DB >> 15523332

Finite element analysis of three designs of an implant-supported molar crown.

Allahyar Geramy1, Steven M Morgano.   

Abstract

STATEMENT OF PROBLEM: The optimal method of implant support for a single mandibular molar crown is controversial because commonly used, threaded, root-form implants developed by Branemark were not originally designed to support individual crowns.
PURPOSE: The purpose of this study was to develop a finite element model of a single mandibular first molar crown supported by (1) a standard 3.75-mm-diameter implant, (2) a 5-mm, wide-diameter implant, and (3) double standard-diameter implants, and to compare the induced displacements as a result of various loading conditions.
MATERIAL AND METHODS: Three-dimensional finite element models were made to simulate the 3 single-molar implant designs. Each model was analyzed with 2 force magnitudes (35 N and 70 N) and with 2 force directions (vertical and 15 degrees to the vertical axis). Displacements in 3-dimensional space as a result of the simulated loading conditions were evaluated along 3 primary axes, mesiodistal, faciolingual, and superior-inferior.
RESULTS: Mesiodistal and buccolingual displacements for the crown supported by the 5-mm-diameter implant were reduced by approximately 50% compared with the crown supported by the 3.75-mm implant when the crowns were loaded at the distobuccal cusp tip or the distal marginal ridge. The double-implant design recorded the least mesiodistal displacement with off-center loading of the crown.
CONCLUSION: When the crown was loaded off-center, the double-implant design produced substantially less displacement when compared with either of the single-implant designs.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15523332     DOI: 10.1016/j.prosdent.2004.08.011

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  16 in total

1.  Stress Distribution Around Single Short Dental Implants: A Finite Element Study.

Authors:  S Vidya Bhat; Priyanka Premkumar; K Kamalakanth Shenoy
Journal:  J Indian Prosthodont Soc       Date:  2014-09-10

2.  Three dimensional finite element analysis of stress distribution around implant with straight and angled abutments in different bone qualities.

Authors:  G Arun Kumar; B Mahesh; Dadu George
Journal:  J Indian Prosthodont Soc       Date:  2013-01-06

3.  Evaluation of stress distribution in bone of different densities using different implant designs: a three-dimensional finite element analysis.

Authors:  K Premnath; J Sridevi; N Kalavathy; Prakash Nagaranjani; M Ranganath Sharmila
Journal:  J Indian Prosthodont Soc       Date:  2012-10-26

4.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

5.  Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar: A Three-Dimensional FEA.

Authors:  Shrikar R Desai; I Karthikeyan; Rika Singh
Journal:  ISRN Dent       Date:  2012-03-07

6.  Anterior Teeth Splinting After Orthodontic Treatment: 3D Analysis Using Finite Element Method.

Authors:  A Geramy; J M Retrouvey; F Sobuti; H Salehi
Journal:  J Dent (Tehran)       Date:  2012-06-30

7.  3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar.

Authors:  Shrikar R Desai; I Karthikeyan; Reetika Gaddale
Journal:  J Indian Soc Periodontol       Date:  2013-11

8.  Stress distribution changes after root canal therapy in canine model: a finite element study.

Authors:  Allahyar Geramy; Mohammad Jafar Eghbal; Sara Ehsani
Journal:  Iran Endod J       Date:  2008-10-01

9.  Numerical study of effect of elastomeric stress absorbers on stress reduction in bone-dental implant interface.

Authors:  Ghalem Mehdi; Abderrahmane Belarbi; Bensmaine Mansouri; Zitouni Azari
Journal:  J Appl Oral Sci       Date:  2015 Jan-Feb       Impact factor: 2.698

10.  Effects of Length and Inclination of Implants on Terminal Abutment Teeth and Implants in Mandibular CL1 Removable Partial Denture Assessed by Three-Dimensional Finite Element Analysis.

Authors:  Amir Fayaz; Alahyar Geramy; Yeganeh Memari; Zahra Rahmani
Journal:  J Dent (Tehran)       Date:  2015-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.