Literature DB >> 8862581

Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles.

L C McDonald1, J Fune, L B Gaido, M P Weinstein, L G Reimer, T M Flynn, M L Wilson, S Mirrett, L B Reller.   

Abstract

Two recent multicenter blood culture studies found that BacT/Alert FAN (FAN) bottles (Organon Teknika, Durham, N.C.) had increased yields in detecting bacteremia and fungemia compared with standard BacT/Alert (STD) bottles. Because the clinical importance of this increase in microbial recovery is unknown, we performed a retrospective analysis to determine the frequency with which FAN bottles were the sole means of detecting an episode of bacteremia. There were 1,047 positive blood cultures in which both study bottles were adequately filled and the organism isolated was judged to be the cause of sepsis: 240 (23%) were positive only in FAN bottles and 73 (7%) were positive only in STD bottles. Of a total of 664 episodes of bacteremia, 126 (19%) were identified only by FAN bottles and 43 (7%) were identified only by STD bottles (P < 0.0001). Episodes detected only by FAN bottles more often were recurrent events (23 of 126, or 18%) than episodes detected only by STD bottles (2 of 43, or 5%) (P < 0.05) and more commonly occurred in patients receiving theoretically effective antibiotic therapy (33 of 126 [26%] versus 4 of 43 [9%]) (P < 0.05). The medical records for patients with 127 of these episodes (92 FAN bottles only; 35 STD bottles only) were available for review. More than half of both FAN bottle-only (60 of 92, or 65%) and STD bottle-only (20 of 35, or 57%) episodes were judged to be clinically important. We conclude that FAN bottles improve the detection of bacteremia and that the majority of the additional episodes detected are clinically important. The benefits of the greater yield in specific patient populations must be balanced against the higher costs of FAN bottles.

Entities:  

Mesh:

Year:  1996        PMID: 8862581      PMCID: PMC229213          DOI: 10.1128/jcm.34.9.2180-2184.1996

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  26 in total

1.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

Review 2.  Manual blood culture systems and the antimicrobial removal device.

Authors:  G V Doern
Journal:  Clin Lab Med       Date:  1994-03       Impact factor: 1.935

3.  In vitro antibiotic removal and bacterial recovery from blood with an antibiotic removal device.

Authors:  N J Lindsey; P E Riely
Journal:  J Clin Microbiol       Date:  1981-03       Impact factor: 5.948

4.  Nosocomial bloodstream infection in critically ill patients. Excess length of stay, extra costs, and attributable mortality.

Authors:  D Pittet; D Tarara; R P Wenzel
Journal:  JAMA       Date:  1994-05-25       Impact factor: 56.272

5.  Controlled comparison of the BACTEC high-blood-volume fungal medium, BACTEC Plus 26 aerobic blood culture bottle, and 10-milliliter isolator blood culture system for detection of fungemia and bacteremia.

Authors:  M L Wilson; T E Davis; S Mirrett; J Reynolds; D Fuller; S D Allen; K K Flint; F Koontz; L B Reller
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

6.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

7.  Clinical impact of rapid in vitro susceptibility testing and bacterial identification.

Authors:  G V Doern; R Vautour; M Gaudet; B Levy
Journal:  J Clin Microbiol       Date:  1994-07       Impact factor: 5.948

8.  Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles.

Authors:  M L Wilson; L J Harrell; S Mirrett; M P Weinstein; C W Stratton; L B Reller
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

9.  Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections.

Authors:  B A Kirkley; K A Easley; J A Washington
Journal:  J Clin Microbiol       Date:  1994-06       Impact factor: 5.948

10.  Controlled evaluation of BacT/alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia.

Authors:  M L Wilson; M P Weinstein; S Mirrett; L G Reimer; R J Feldman; C R Chuard; L B Reller
Journal:  J Clin Microbiol       Date:  1995-09       Impact factor: 5.948

View more
  16 in total

1.  Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults.

Authors:  M L Wilson; S Mirrett; F T Meredith; M P Weinstein; V Scotto; L B Reller
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

2.  Rapid detection of sepsis complicating acute necrotizing pancreatitis using polymerase chain reaction.

Authors:  W Z Zhang; T Q Han; Y Q Tang; S D Zhang
Journal:  World J Gastroenterol       Date:  2001-04       Impact factor: 5.742

3.  Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT.

Authors:  K K Krisher; P Gibb; S Corbett; D Church
Journal:  J Clin Microbiol       Date:  2001-08       Impact factor: 5.948

Review 4.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

Review 5.  Updated review of blood culture contamination.

Authors:  Keri K Hall; Jason A Lyman
Journal:  Clin Microbiol Rev       Date:  2006-10       Impact factor: 26.132

6.  Using the polymerase chain reaction coupled with denaturing gradient gel electrophoresis to investigate the association between bacterial translocation and systemic inflammatory response syndrome in predicted acute severe pancreatitis.

Authors:  Callum B Pearce; Vitaly Zinkevich; Iwona Beech; Viera Funjika; Ana Garcia Ruiz; Afraa Aladawi; Hamish D Duncan
Journal:  World J Gastroenterol       Date:  2005-12-07       Impact factor: 5.742

7.  Relevance of routine use of the anaerobic blood culture bottle.

Authors:  Patrick Grohs; Jean-Luc Mainardi; Isabelle Podglajen; Xavier Hanras; C Eckert; A Buu-Hoï; E Varon; Laurent Gutmann
Journal:  J Clin Microbiol       Date:  2007-06-20       Impact factor: 5.948

Review 8.  Blood culture contamination: persisting problems and partial progress.

Authors:  Melvin P Weinstein
Journal:  J Clin Microbiol       Date:  2003-06       Impact factor: 5.948

9.  High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care.

Authors:  R Amarsy-Guerle; F Mougari; H Jacquier; J Oliary; H Benmansour; J Riahi; B Berçot; L Raskine; E Cambau
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-02-04       Impact factor: 3.267

Review 10.  Developments for improved diagnosis of bacterial bloodstream infections.

Authors:  A J M Loonen; P F G Wolffs; C A Bruggeman; A J C van den Brule
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-05-22       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.