Literature DB >> 15448403

Phase and microstructural development in alumina sol-gel coatings on CoCr alloy.

I J Bae1, O C Standard, G J Roger, D Brazil.   

Abstract

Phase transformation of gamma-Al(2)O(3) to alpha-Al(2)O(3) in alumina sol gel coatings on biomedical CoCr alloy was studied as function of heat treatment temperature and time. Transformation in unseeded coatings was significant only above approximately 1200 degrees C. Addition of alpha-Al(2)O(3) seed particles having an average size of approximately 40 nm lowered the phase transformation temperature to around 800 degrees C. These particles were considered to act as heterogeneous nucleation sites for epitaxial growth of the alpha-Al(2)O(3) phase. The kinetics and activation energy (420 kJ/mol) for the phase transformation in the seeded coatings were similar to those reported for seeded monolithic alumina gels indicating that the transformation mechanism is the same in the two material configurations. Avrami growth parameters indicated that the mechanism was diffusion controlled and invariant over the temperature range studied but that growth was possibly constrained by the finite size of the seed particles and/or coating thickness. The phase transformation occurred by the growth of alpha-Al(2)O(3) grains at the expense of the precursor fine-grained gamma-Al(2)O(3) matrix and near-complete transformation coincided with physical impingement of the growing grains. The grain size at impingement was approximately 100 nm which agreed well with that predicted from the theoretical linear spacing of seed particles in the initial sol.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15448403     DOI: 10.1023/B:JMSM.0000042681.25746.74

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  7 in total

Review 1.  Pathology of the bone-implant interfaces.

Authors:  N al-Saffar; P A Revell
Journal:  J Long Term Eff Med Implants       Date:  1999

2.  Ten-year socket wear in 66 hip arthroplasties. Ceramic versus metal heads.

Authors:  H M Schüller; R K Marti
Journal:  Acta Orthop Scand       Date:  1990-06

3.  The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy.

Authors:  T P Schmalzried; L M Kwong; M Jasty; R C Sedlacek; T C Haire; D O O'Connor; C R Bragdon; J M Kabo; A J Malcolm; W H Harris
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

4.  Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements.

Authors:  M Semlitsch; H G Willert
Journal:  Proc Inst Mech Eng H       Date:  1997       Impact factor: 1.617

5.  Polyethylene and titanium alloy particles reduce bone formation. Dose-dependence in bone harvest chamber experiments in rabbits.

Authors:  S Goodman; P Aspenberg; Y Song; D Regula; L Lidgren
Journal:  Acta Orthop Scand       Date:  1996-12

Review 6.  Mechanism and clinical significance of wear debris-induced osteolysis.

Authors:  H C Amstutz; P Campbell; N Kossovsky; I C Clarke
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

7.  Comparison of alumina-polyethylene and metal-polyethylene in clinical trials.

Authors:  L P Zichner; H G Willert
Journal:  Clin Orthop Relat Res       Date:  1992-09       Impact factor: 4.176

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.