Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements.

M Semlitsch1, H G Willert.   

Abstract

In the course of 30 years of hip endoprosthetics, a number of material combinations for the cups and balls of total hip prostheses have proven successful under clinical conditions. Favourably priced hip prostheses with polyethylene cups and metal balls are available for older patients with a moderate range of activity. Polyethylene wear of 100-300 microns/year is to be expected with these models. Ceramic balls (aluminium oxide for diameters 32 and 28 mm and zirconium oxide for 22 mm) paired with polyethylene cups are recommended for patients with a life expectancy of 10 to 20 years, because the expected polyethylene wear rate with this material combination is only 50-150 microns/year. In other words, the life cycle of the polyethylene cup is doubled, when it is paired with a ceramic ball. A similar polyethylene wear rate is also to be expected with oxygen-deep-hardened TiAlNb metal balls, which are currently the subject of a clinical field study. Last but not least, CoCrMoC metal-metal and Al2O3 ceramic ceramic pairings, which have the lowest wear rate of 2-20 microns/year, are available for highly active patients with a life expectancy of more than 20 years. As far as the cup-ball pairing is concerned and under the current pressure of costs, the surgeon should be able to select the optimum hip prosthesis model for every patient from these three categories.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9141893     DOI: 10.1243/0954411971534700

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  6 in total

1.  Improving the durability of total joint replacement.

Authors:  J P Waddell
Journal:  CMAJ       Date:  1999-11-02       Impact factor: 8.262

Review 2.  Bearing surfaces in hip replacement - Evolution and likely future.

Authors:  Narinder Kumar; Gen N C Arora; Barun Datta
Journal:  Med J Armed Forces India       Date:  2014-08-04

3.  Phase and microstructural development in alumina sol-gel coatings on CoCr alloy.

Authors:  I J Bae; O C Standard; G J Roger; D Brazil
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

4.  Wear behavior of carbide coated Co-Cr-Mo implant alloy.

Authors:  N S Vandamme; B H Wayman; L D T Topoleski
Journal:  J Mater Sci Mater Med       Date:  2003-01       Impact factor: 3.896

5.  Tribology of total hip arthroplasty prostheses: What an orthopaedic surgeon should know.

Authors:  Claude B Rieker
Journal:  EFORT Open Rev       Date:  2017-03-13

6.  Comparison of conventional polyethylene wear and signs of cup failure in two similar total hip designs.

Authors:  Thomas B Pace; Kevin C Keith; Estefania Alvarez; Rebecca G Snider; Stephanie L Tanner; John D Desjardins
Journal:  Adv Orthop       Date:  2013-04-11