Literature DB >> 10847971

Pathology of the bone-implant interfaces.

N al-Saffar1, P A Revell.   

Abstract

Joint replacement surgery has a wide clinical application as a successful technique. However, the release of biomaterial in particulate form from various implant components has been implicated as a cause of two major clinical complications: 1) bone lysis with or without aseptic loosening, and 2) dissemination of wear particles to distant sites with adverse local or systemic cellular responses. This review focuses on the analysis of the clinical material obtained at the time of revision operations and its value in identifying the pathological processes taking place within the bone-implant microenvironment. Important issues discussed include the incidence of infection, characterization of wear particles, particle-cell interactions, local histopathological changes that lead to the formation of erosive inflammatory lesions next to the bone, sensitivity reactions, tumor formation, and the induction of inflammatory factors and cytokines that can influence the rate of bone resorption versus bone formation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10847971

Source DB:  PubMed          Journal:  J Long Term Eff Med Implants        ISSN: 1050-6934


  16 in total

1.  The expression of CD44 in archival paraffin embedded interface tissues of failed orthopaedic implants.

Authors:  Taneisha McFarlane; P A Revell
Journal:  J Mater Sci Mater Med       Date:  2004-04       Impact factor: 3.896

2.  Detection of micro- and nano-sized biocompatible particles in the blood.

Authors:  A M Gatti; S Montanari; E Monari; A Gambarelli; F Capitani; B Parisini
Journal:  J Mater Sci Mater Med       Date:  2004-04       Impact factor: 3.896

3.  Phenotypic characteristics of T lymphocytes in the interfacial tissue of aseptically loosened prosthetic joints.

Authors:  B Hercus; P A Revell
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

Review 4.  [Wear particles: key to aseptic prosthetic loosening?].

Authors:  M Otto; J Kriegsmann; T Gehrke; S Bertz
Journal:  Pathologe       Date:  2006-11       Impact factor: 1.011

Review 5.  The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses.

Authors:  Peter A Revell
Journal:  J R Soc Interface       Date:  2008-11-06       Impact factor: 4.118

6.  Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo.

Authors:  V Lorber; A C Paulus; A Buschmann; B Schmitt; T M Grupp; V Jansson; Sandra Utzschneider
Journal:  J Mater Sci Mater Med       Date:  2013-09-26       Impact factor: 3.896

7.  Tunnel enlargement after anterior cruciate ligament reconstruction in patients with post-operative septic arthritis.

Authors:  R Iorio; A Vadalà; I Di Vavo; A De Carli; F Conteduca; G Argento; A Ferretti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-07-01       Impact factor: 4.342

8.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

9.  Phase and microstructural development in alumina sol-gel coatings on CoCr alloy.

Authors:  I J Bae; O C Standard; G J Roger; D Brazil
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

10.  Tunnel enlargement and changes in synovial fluid cytokine profile following anterior cruciate ligament reconstruction with patellar tendon and hamstring tendon autografts.

Authors:  S P Zysk; P Fraunberger; A Veihelmann; M Dörger; T Kalteis; M Maier; C Pellengahr; H J Refior
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-09-20       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.