Literature DB >> 2371818

Ten-year socket wear in 66 hip arthroplasties. Ceramic versus metal heads.

H M Schüller1, R K Marti.   

Abstract

Radiographic measurements of polyethylene socket wear were performed in 33 hip prostheses with an AI2O3-ceramic head and 33 prostheses with a metal head. At 9-11 years, the average reduction of the diameter of the polyethylene was 0.26 and 0.96 mm, respectively, in the ceramic and the metal group. However, the number of clinically proven or radiographically suspected loosenings did not differ between the two groups.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2371818     DOI: 10.3109/17453679008993508

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  13 in total

1.  Bearing surfaces in total joint replacement.

Authors:  R B Welch; G Levengood
Journal:  West J Med       Date:  1991-08

2.  Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: a ten-year follow-up with radiostereometry.

Authors:  Jon Dahl; Per Söderlund; Bo Nivbrant; Lars Nordsletten; Stephan M Röhrl
Journal:  Int Orthop       Date:  2011-08-26       Impact factor: 3.075

3.  Alumina heads minimize wear and femoral osteolysis progression after isolated simple acetabular revision.

Authors:  Philippe Hernigou; Nicolas Dupuy; Olivier Pidet; Yashuhiro Homma; Charles Henri Flouzat Lachaniette
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

5.  Phase and microstructural development in alumina sol-gel coatings on CoCr alloy.

Authors:  I J Bae; O C Standard; G J Roger; D Brazil
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

6.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11

7.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

8.  How safe are ceramic heads as hip endoprostheses? A series of three head fractures within 3 months.

Authors:  A Burckhardt; C Berberat
Journal:  Arch Orthop Trauma Surg       Date:  1993       Impact factor: 3.067

9.  Preliminary tribological evaluation of nanostructured diamond coatings against ultra-high molecular weight polyethylene.

Authors:  Michael R Hill; Shane A Catledge; Valeriy Konovalov; William C Clem; Shafiul A Chowdhury; Brandon S Etheridge; Andrei Stanishevsky; Jack E Lemons; Yogesh K Vohra; Alan W Eberhardt
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-04       Impact factor: 3.368

10.  Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene.

Authors:  Kevin L Garvin; Curtis W Hartman; Jimmi Mangla; Nathan Murdoch; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2008-10-23       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.