Literature DB >> 15447752

Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy.

Akira Horiuchi1, Yoshiko Nakayama, Masashi Kajiyama, Hideyasu Fujii, Naoki Tanaka.   

Abstract

OBJECTIVES: Although variable-stiffness colonoscopes have been developed, difficult or incomplete colonoscopies occasionally occur. The aim of this study was to evaluate the usefulness of a small-caliber, variable-stiffness colonoscope (scVSC) as a backup in patients with difficult or incomplete colonoscopies.
METHODS: First, we retrospectively reviewed the cecal intubation rate of colonoscopies in which an adult standard colonoscope (AC) was immediately switched to an scVSC in all patients in whom a colonoscopy with an AC was incomplete. Second, 374 consecutive patients were randomized to undergo colonoscopy with a pediatric variable-stiffness colonoscope (PVSC, n = 123), AC (n = 125), or scVSC (n = 126). The scVSC was used by the same endoscopist to reattempt colonoscopy immediately after colonoscopy with a PVSC or an AC had been assessed as difficult or incomplete. The cecal intubation rate and time and the ancillary maneuvers used were evaluated.
RESULTS: Fifty-two (2.5%) of the 2,056 attempted colonoscopies with an AC did not reach the cecum. Fifty-one of the 52 patients (98.1%) had complete colonoscopies after the switch from the AC to the scVSC. The initial intubation rate and time were not statistically different among the groups: PVSC, 95% and 6.8 min; AC, 91% and 7.5 min; and scVSC, 98% and 8.2 min. Cecal intubation was achieved in all five patients (100%) and in 10 out of 11 (91%) patients, respectively, after the PVSC or AC was switched to the scVSC.
CONCLUSIONS: The completion rate markedly improved after switching from an AC or PVSC to an scVSC in difficult or incomplete colonoscopies, although the scVSC does not appear to offer any distinct advantage over the AC or PVSC for routine colonoscopies.

Entities:  

Mesh:

Year:  2004        PMID: 15447752     DOI: 10.1111/j.1572-0241.2004.40201.x

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  12 in total

1.  Colonoscopy using a small-caliber colonoscope with passive-bending after incomplete colonoscopy due to sharp angulation or pain.

Authors:  Koichiro Sato; Fumiko Shigiyama; Sayo Ito; Tomoyuki Kitagawa; Kenji Tominaga; Takeshi Suzuki; Iruru Maetani
Journal:  Surg Endosc       Date:  2013-05-31       Impact factor: 4.584

2.  Magnifying gastroscopy using a soft black hood for difficult colonoscopy.

Authors:  Hisashi Nakamura; Kuangi Fu; Akihiko Yamamura
Journal:  Surg Endosc       Date:  2011-04-13       Impact factor: 4.584

3.  Safety and effectiveness of propofol sedation during and after outpatient colonoscopy.

Authors:  Akira Horiuchi; Yoshiko Nakayama; Masashi Kajiyama; Naoyuki Kato; Tetsuya Kamijima; Yasuyuki Ichise; Naoki Tanaka
Journal:  World J Gastroenterol       Date:  2012-07-14       Impact factor: 5.742

4.  A prospective randomized study of the use of an ultrathin colonoscope versus a pediatric colonoscope in sedation-optional colonoscopy.

Authors:  Koichiro Sato; Sayo Ito; Tomoyuki Kitagawa; Koichi Hirahata; Daisuke Hihara; Kenji Tominaga; Ichiro Yasuda; Iruru Maetani
Journal:  Surg Endosc       Date:  2017-05-09       Impact factor: 4.584

5.  Patient factors associated with a faster insertion of the colonoscope.

Authors:  Rodolfo Arcovedo; Charles Larsen; Hector Salazar Reyes
Journal:  Surg Endosc       Date:  2006-12-06       Impact factor: 4.584

Review 6.  Methods of reducing discomfort during colonoscopy.

Authors:  Felix W Leung
Journal:  Dig Dis Sci       Date:  2008-06       Impact factor: 3.199

7.  Routine colonoscopy with a standard gastroscope. A randomized comparative trial in a western population.

Authors:  Till Wehrmann; Izabel Lechowicz; Ksenia Martchenko; Andrea Riphaus
Journal:  Int J Colorectal Dis       Date:  2008-04       Impact factor: 2.571

8.  Factors associated with incomplete colonoscopy at a Japanese academic hospital.

Authors:  Shigeo Koido; Toshifumi Ohkusa; Kosaburo Nakae; Tetsuji Yokoyama; Tomoyoshi Shibuya; Naoto Sakamoto; Kan Uchiyama; Hiroshi Arakawa; Taro Osada; Akihito Nagahara; Sumio Watanabe; Hisao Tajiri
Journal:  World J Gastroenterol       Date:  2014-06-14       Impact factor: 5.742

9.  Clinical usefulness of single-balloon endoscopy in patients with previously incomplete colonoscopy.

Authors:  Kiyonori Kobayashi; Miyuki Mukae; Taishi Ogawa; Kaoru Yokoyama; Miwa Sada; Wasaburo Koizumi
Journal:  World J Gastrointest Endosc       Date:  2013-03-16

10.  Does the variable-stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope.

Authors:  Qin Xie; Bin Chen; Liu Liu; Huatian Gan
Journal:  BMC Gastroenterol       Date:  2012-10-24       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.