Comparison of polypropylene and polyethylene terephthalate (Dacron) meshes for abdominal wall hernia repair: a chemical and morphological study.

P Bracco1, V Brunella, L Trossarelli, A Coda, F Botto-Micca.   

Abstract

For the first time, by scanning electron microscopy (SEM), polypropylene (PP) excised meshes (ethylene oxide sterilized) for abdominal wall hernia repair have been shown to be greatly damaged physically, independently of the implantation time, while the polyethylene terephthalate (PET), or Dacron, ones (gamma radiation sterilized), did not undergo alterations due to the sterilization process and were not damaged, even after long implantation periods. Fourier-Transform Infrared Spectroscopy (FTIR) study of PP and PET excised meshes, as well as of their extracts with cyclohexane, has shown the presence of species, such as squalene, palmitic and stearic acid, in some cases, cholesterol, transferred from the surrounding tissues to the polymer during the implantation period. In the case of PP meshes, these small organic molecules would reduce physical and mechanical properties of the material. A hypothesis is presented to account for the better behavior (not in the clinical sense) of PET meshes.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15365886     DOI: 10.1007/s10029-004-0281-y

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  8 in total

1.  Analysis of products diffused into UHMWPE prosthetic components in vivo.

Authors:  L Costa; P Bracco; E B del Prever; M P Luda; L Trossarelli
Journal:  Biomaterials       Date:  2001-02       Impact factor: 12.479

2.  Structural alterations of prosthetic meshes in humans.

Authors:  A Coda; R Bendavid; F Botto-Micca; M Bossotti; A Bona
Journal:  Hernia       Date:  2002-10-18       Impact factor: 4.739

Review 3.  The outcomes of nonabsorbable mesh placed within the abdominal cavity: literature review and clinical experience.

Authors:  G J Morris-Stiff; L E Hughes
Journal:  J Am Coll Surg       Date:  1998-03       Impact factor: 6.113

4.  Stability of performances of vascular prostheses retrospective study of 22 cases of human implanted prostheses.

Authors:  E Vinard; R Eloy; J Descotes; J R Brudon; H Guidicelli; J L Magne; P Patra; R Berruet; A Huc; J Chauchard
Journal:  J Biomed Mater Res       Date:  1988-07

5.  Molecular weight characterization of virgin and explanted polyester arterial prostheses.

Authors:  J M Maarek; R Guidoin; M Aubin; R E Prud'homme
Journal:  J Biomed Mater Res       Date:  1984-10

6.  Shrinking of polypropylene mesh in vivo: an experimental study in dogs.

Authors:  U Klinge; B Klosterhalfen; M Müller; A P Ottinger; V Schumpelick
Journal:  Eur J Surg       Date:  1998-12

7.  In vivo UHMWPE biodegradation of retrieved prosthesis.

Authors:  L Costa; M P Luda; L Trossarelli; E M Brach del Prever; M Crova; P Gallinaro
Journal:  Biomaterials       Date:  1998-08       Impact factor: 12.479

8.  Oxidation in orthopaedic UHMWPE sterilized by gamma-radiation and ethylene oxide.

Authors:  L Costa; M P Luda; L Trossarelli; E M Brach del Prever; M Crova; P Gallinaro
Journal:  Biomaterials       Date:  1998 Apr-May       Impact factor: 12.479

  8 in total
  6 in total

1.  An elastomeric patch electrospun from a blended solution of dermal extracellular matrix and biodegradable polyurethane for rat abdominal wall repair.

Authors:  Yi Hong; Keisuke Takanari; Nicholas J Amoroso; Ryotaro Hashizume; Ellen P Brennan-Pierce; John M Freund; Stephen F Badylak; William R Wagner
Journal:  Tissue Eng Part C Methods       Date:  2011-11-10       Impact factor: 3.056

Review 2.  Improving outcomes in hernia repair by the use of light meshes--a comparison of different implant constructions based on a critical appraisal of the literature.

Authors:  Dirk Weyhe; Orlin Belyaev; Christophe Müller; Kirsten Meurer; Karl-Heinz Bauer; Georgios Papapostolou; Waldemar Uhl
Journal:  World J Surg       Date:  2007-01       Impact factor: 3.352

3.  Re: Totally extraperitoneal repair of inguinal hernias: some remarks on technical details.

Authors:  Christophe Roger Berney
Journal:  Langenbecks Arch Surg       Date:  2013-02-03       Impact factor: 3.445

4.  Integrin-directed modulation of macrophage responses to biomaterials.

Authors:  Toral D Zaveri; Jamal S Lewis; Natalia V Dolgova; Michael J Clare-Salzler; Benjamin G Keselowsky
Journal:  Biomaterials       Date:  2014-01-24       Impact factor: 12.479

5.  Polypropylene as a reinforcement in pelvic surgery is not inert: comparative analysis of 100 explants.

Authors:  Arnaud Clavé; Hannah Yahi; Jean-Claude Hammou; Suzelei Montanari; Pierre Gounon; Henri Clavé
Journal:  Int Urogynecol J       Date:  2010-01-06       Impact factor: 2.894

6.  Materials characterization and histological analysis of explanted polypropylene, PTFE, and PET hernia meshes from an individual patient.

Authors:  A J Wood; M J Cozad; D A Grant; A M Ostdiek; S L Bachman; S A Grant
Journal:  J Mater Sci Mater Med       Date:  2013-01-31       Impact factor: 3.896

  6 in total