Literature DB >> 6242474

Molecular weight characterization of virgin and explanted polyester arterial prostheses.

J M Maarek, R Guidoin, M Aubin, R E Prud'homme.   

Abstract

The macromolecular properties of 17 virgin commercial arterial prostheses and a series of explanted prostheses, both manufactured from poly(ethylene terephthalate) (PET) yarns, have been studied by gel permeation chromatography (GPC) and by differential scanning calorimetry (DSC). Only small differences were found between the average molecular weights and the degree of crystallinity of the unused reference grafts. A broadening of the DSC curves was observed for the prostheses containing texturized yarns compared with those made solely from flat, untexturized yarns. This broadening may be due to greater heterogeneity of the crystal sizes caused by the texturizing process and to the use of two or more different yarns with dissimilar thermal histories in the same prosthesis. Average molecular weights of the explant series were significantly lower than those of the corresponding reference grafts but almost time independent. The polydispersity index and the degree of crystallinity of the explants remained constant as a function of time. These results are discussed in regard to others available in the literature.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6242474     DOI: 10.1002/jbm.820180804

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

Review 1.  Mesh biocompatibility: effects of cellular inflammation and tissue remodelling.

Authors:  Karsten Junge; Marcel Binnebösel; Klaus T von Trotha; Raphael Rosch; Uwe Klinge; Ulf P Neumann; Petra Lynen Jansen
Journal:  Langenbecks Arch Surg       Date:  2011-04-01       Impact factor: 3.445

Review 2.  Biocompatibility of prosthetic meshes in abdominal surgery.

Authors:  Marcel Binnebösel; Klaus T von Trotha; Petra Lynen Jansen; Joachim Conze; Ulf P Neumann; Karsten Junge
Journal:  Semin Immunopathol       Date:  2011-01-12       Impact factor: 9.623

3.  In vivo biostability of polymeric spine implants: retrieval analyses from a United States investigational device exemption study.

Authors:  Ming Shen; Kai Zhang; Petra Koettig; William C Welch; John M Dawson
Journal:  Eur Spine J       Date:  2011-05-03       Impact factor: 3.134

4.  Comparison of polypropylene and polyethylene terephthalate (Dacron) meshes for abdominal wall hernia repair: a chemical and morphological study.

Authors:  P Bracco; V Brunella; L Trossarelli; A Coda; F Botto-Micca
Journal:  Hernia       Date:  2004-09-10       Impact factor: 4.739

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.