Abstract

INTRODUCTION: In light of the fact that, to date, no information is available about titanium relative to its application in prosthetic material employed for hernial repair, the aim of the present work was to evaluate the fundamental possibilities of titanium-coated polypropylene meshes.
MATERIALS AND METHODS: In experiments with animals, two groups, each containing 11 pigs, received either a heavyweight polypropylene mesh (Atrium) or an identical but titanium-coated mesh (titanium-coated Atrium) implanted into the left groin using the totally endoscopic extraperitoneal patchplasty technique.
RESULTS: A significant difference in the shrinkage behavior between conventional Atrium and titanium-coated Atrium was found (14.9 vs. 8.8%, p < 0.05). Furthermore, the partial volume of the inflammatory infiltrate also proved to be smaller with the titanium-coated mesh (14.9 vs. 12.4%). In addition, Ki-67 expression was lower in the group implanted with titanium-coated mesh (21.0 vs. 15.0%). No difference was observed with regard to the apoptosis index (7.6 vs. 6.5).
CONCLUSIONS: Heavyweight titanium-coated polypropylene meshes induce a less pronounced foreign body reaction in comparison with identical meshes with no titanium coating, which, since the amount of material implanted is identical, must be attributed solely to the titanium coating. Copyright 2004 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15359095     DOI: 10.1159/000079917

Source DB:  PubMed          Journal:  Eur Surg Res        ISSN: 0014-312X            Impact factor:   1.745


  28 in total

1.  Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model.

Authors:  C Schug-Pass; H Lippert; F Köckerling
Journal:  Surg Endosc       Date:  2009-05-23       Impact factor: 4.584

2.  Randomized clinical trial of laparoscopic hernia repair comparing titanium-coated lightweight mesh and medium-weight composite mesh.

Authors:  Alfredo Moreno-Egea; Andrés Carrillo-Alcaraz; Víctor Soria-Aledo
Journal:  Surg Endosc       Date:  2012-07-07       Impact factor: 4.584

Review 3.  Which mesh for hernia repair?

Authors:  C N Brown; J G Finch
Journal:  Ann R Coll Surg Engl       Date:  2010-05       Impact factor: 1.891

Review 4.  Improving outcomes in hernia repair by the use of light meshes--a comparison of different implant constructions based on a critical appraisal of the literature.

Authors:  Dirk Weyhe; Orlin Belyaev; Christophe Müller; Kirsten Meurer; Karl-Heinz Bauer; Georgios Papapostolou; Waldemar Uhl
Journal:  World J Surg       Date:  2007-01       Impact factor: 3.352

5.  A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine model.

Authors:  C Schug-Pass; C Tamme; F Sommerer; A Tannapfel; H Lippert; F Köckerling
Journal:  Surg Endosc       Date:  2007-10-26       Impact factor: 4.584

6.  Does the additional application of a polylactide film (SurgiWrap) to a lightweight mesh (TiMesh) reduce adhesions after laparoscopic intraperitoneal implantation procedures? Experimental results obtained with the laparoscopic porcine model.

Authors:  Christine Schug-Pass; Florian Sommerer; Andrea Tannapfel; Hans Lippert; Ferdinand Köckerling
Journal:  Surg Endosc       Date:  2008-04-24       Impact factor: 4.584

7.  Biological Matrices and Synthetic Meshes Used in Implant-based Breast Reconstruction - a Review of Products Available in Germany.

Authors:  M Dieterich; A Faridi
Journal:  Geburtshilfe Frauenheilkd       Date:  2013-11       Impact factor: 2.915

8.  Adhesion prevention in ventral hernia repair: an experimental study comparing three lightweight porous meshes recommended for intraperitoneal use.

Authors:  L D'Amore; F Ceci; S Mattia; M Fabbi; P Negro; F Gossetti
Journal:  Hernia       Date:  2016-10-18       Impact factor: 4.739

9.  Mesh fixation with fibrin glue (Tissucol/Tisseel) in hernia repair dependent on the mesh structure--is there an optimum fibrin-mesh combination?--investigations on a biomechanical model.

Authors:  Christine Schug-Pass; Hans Lippert; Ferdinand Köckerling
Journal:  Langenbecks Arch Surg       Date:  2009-01-31       Impact factor: 3.445

10.  A randomised, multi-centre, prospective, double blind pilot-study to evaluate safety and efficacy of the non-absorbable Optilene Mesh Elastic versus the partly absorbable Ultrapro Mesh for incisional hernia repair.

Authors:  Christoph Seiler; Petra Baumann; Peter Kienle; Andreas Kuthe; Jens Kuhlgatz; Rainer Engemann; Moritz V Frankenberg; Hanns-Peter Knaebel
Journal:  BMC Surg       Date:  2010-07-12       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.