Literature DB >> 16612550

Application and assessment of a robust elastic motion correction algorithm to dynamic MRI.

K-H Herrmann1, S Wurdinger, D R Fischer, I Krumbein, M Schmitt, G Hermosillo, K Chaudhuri, A Krishnan, M Salganicoff, W A Kaiser, J R Reichenbach.   

Abstract

The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).

Entities:  

Mesh:

Year:  2006        PMID: 16612550     DOI: 10.1007/s00330-006-0224-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  9 in total

1.  Elastic matching of dynamic MR mammographic images.

Authors:  R Lucht; M V Knopp; G Brix
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

3.  Validation of nonrigid image registration using finite-element methods: application to breast MR images.

Authors:  Julia A Schnabel; Christine Tanner; Andy D Castellano-Smith; Andreas Degenhard; Martin O Leach; D Rodney Hose; Derek L G Hill; David J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

4.  Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint.

Authors:  Torsten Rohlfing; Calvin R Maurer; David A Bluemke; Michael A Jacobs
Journal:  IEEE Trans Med Imaging       Date:  2003-06       Impact factor: 10.048

5.  Fast free-form deformable registration via calculus of variations.

Authors:  Weiguo Lu; Ming-Li Chen; Gustavo H Olivera; Kenneth J Ruchala; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

6.  Large deformation inverse consistent elastic image registration.

Authors:  Jianchun He; Gary E Christensen
Journal:  Inf Process Med Imaging       Date:  2003-07

Review 7.  Contrast-enhanced MRI of the breast: accuracy, value, controversies, solutions.

Authors:  S H Heywang-Köbrunner; P Viehweg; A Heinig; C Küchler
Journal:  Eur J Radiol       Date:  1997-02       Impact factor: 3.528

8.  Undetected malignancies of the breast: dynamic contrast-enhanced MR imaging at 1.0 T.

Authors:  Andrea Teifke; Alexander Hlawatsch; Thomas Beier; Toni Werner Vomweg; Simin Schadmand; Markus Schmidt; Hans-Anton Lehr; Manfred Thelen
Journal:  Radiology       Date:  2002-09       Impact factor: 11.105

9.  Development and validation of an algorithm for registration of serial 3D MR breast data sets.

Authors:  Jürgen R Reichenbach; Jens Hopfe; Matthias E Bellemann; Werner A Kaiser
Journal:  MAGMA       Date:  2002-06       Impact factor: 2.533

  9 in total
  3 in total

1.  Improvement of gagCEST imaging in the human lumbar intervertebral disc by motion correction.

Authors:  Anja Müller-Lutz; Christoph Schleich; Benjamin Schmitt; Melike Topgöz; Gael Pentang; Gerald Antoch; Hans-Jörg Wittsack; Falk Miese
Journal:  Skeletal Radiol       Date:  2014-10-23       Impact factor: 2.199

2.  Impact of nonrigid motion correction technique on pixel-wise pharmacokinetic analysis of free-breathing pulmonary dynamic contrast-enhanced MR imaging.

Authors:  Junichi Tokuda; Hatsuho Mamata; Ritu R Gill; Nobuhiko Hata; Ron Kikinis; Robert F Padera; Robert E Lenkinski; David J Sugarbaker; Hiroto Hatabu
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

3.  3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP.

Authors:  Zhaoyang Fan; John Sheehan; Xiaoming Bi; Xin Liu; James Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.