Literature DB >> 15348444

Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior.

J M García Páez1, E Jorge Herrero, M Martín Maestro, A Rocha, B Arenaz, J L Castillo-Olivares, A Carrera Sanmartín, A Cordon, I Millán.   

Abstract

Careful selection of the biological tissue to be used in cardiac bioprostheses and a thorough knowledge of its mechanical behavior, facilitating both the prediction of this behavior and the interactions between the tissue and the other materials employed, is the best approach to designing a durable implant. For this purpose, a study involving uniaxial tensile testing of calf pericardium was carried out. Two sets of three contiguous strips of tissue were obtained from each pericardial membrane, to perform a total of 144 trials. Two samples were sewn with one of four commercially available suture materials: Gore-Tex, nylon, Prolene and silk. In each set of three samples, the center strip remained intact and unsutured to serve as a control, while the left-hand strip was sutured at a 45 degrees angle with respect to the longitudinal axis and the right-hand strip was sewn at a 90 degrees angle. All the samples were tested until rupture. The results demonstrated a significant loss of mean load (p<0.01) in the sutured samples at rupture. The angle of the suture had no influence on these results, although the stress/strain curves showed that, as the tensile stress increased, the mechanical behaviors were less uniform. The rupture of the collagen fibers could explain this phenomenon. The pericardium sutured with Gore-Tex presented a greater strain, or deformation (elongation), at lower levels of stress, regardless of the angle of the suture. The tissue selection criteria, based on the use of paired samples, enabled a correct prediction of the mechanical behavior of the tissue, with excellent correlation coefficients (>0.98) and a high degree of homogeneity in the results.

Entities:  

Year:  2003        PMID: 15348444     DOI: 10.1023/a:1023258700845

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  24 in total

1.  Is cutting stress responsible for the limited durability of heart valve bioprostheses?

Authors:  J M García Paez; A Carrera San Martín; J V García Sestafe; I Millán; E Jorge; I Candela; J L Castillo-Olivares
Journal:  J Thorac Cardiovasc Surg       Date:  1990-10       Impact factor: 5.209

2.  Selection and interaction of biomaterials used in the construction of cardiac bioprostheses.

Authors:  A Carrera San Martin; J M García Paez; J V García Sestafe; E Jorge Herrero; J Salvador; A Cordón; J L Castillo-Olivares
Journal:  J Biomed Mater Res       Date:  1998-03-15

Review 3.  Prosthetic heart valves.

Authors:  W Vongpatanasin; L D Hillis; R A Lange
Journal:  N Engl J Med       Date:  1996-08-08       Impact factor: 91.245

4.  Temporal changes in the surgical pathology of prosthetic aortic valves: a study of 157 cases spanning 26 years (1970-1995).

Authors:  P D Kent; H D Tazelaar; W D Edwards; T A Orszulak
Journal:  Cardiovasc Pathol       Date:  1998 Jan-Feb       Impact factor: 2.185

5.  Biological valves beyond fifteen years: the Wessex experience.

Authors:  T J Edwards; S A Livesey; I A Simpson; J L Monro; J K Ross
Journal:  Ann Thorac Surg       Date:  1995-08       Impact factor: 4.330

6.  Reoperation in biological and mechanical valve populations: fate of the reoperative patient.

Authors:  G F Tyers; W R Jamieson; A I Munro; E Germann; L H Burr; R T Miyagishima; H Ling
Journal:  Ann Thorac Surg       Date:  1995-08       Impact factor: 4.330

7.  Analysis of shearing stress in the limited durability of bovine pericardium used as a biomaterial.

Authors:  A Carrera San Martin; J M García Paez; J V García Sestafe; E J Herrero; R Navidad; A Cordón; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  1998-02       Impact factor: 3.896

Review 8.  Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses.

Authors:  S C Cannegieter; F R Rosendaal; E Briët
Journal:  Circulation       Date:  1994-02       Impact factor: 29.690

9.  Collagen fiber architecture of bovine pericardium.

Authors:  M S Sacks; C J Chuong; R More
Journal:  ASAIO J       Date:  1994 Jul-Sep       Impact factor: 2.872

10.  Study of the calcification of bovine pericardium: analysis of the implication of lipids and proteoglycans.

Authors:  E Jorge-Herrero; P Fernández; M Gutiérrez; J L Castillo-Olivares
Journal:  Biomaterials       Date:  1991-09       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.