Biological valves beyond fifteen years: the Wessex experience.

T J Edwards1, S A Livesey, I A Simpson, J L Monro, J K Ross.   

Abstract

Between 1975 and 1979, 443 biological valves (298 Carpentier-Edwards, 134 homograft, and 11 Hancock valves) were implanted in 415 patients (age, 16 to 77 years; mean, 59 years) with an operative mortality of 2.9%. Total follow-up was 4,248 patient-years. Overall event-free survival was 60% +/- 1.5% (standard deviation) at 10 years and 29% +/- 1.4% at 15 years. Ten-year and 15-year event-free survival were 72% +/- 3.4% and 41% +/- 3.3% for aortic homografts, 62% +/- 3% and 33% +/- 2.8% for isolated aortic xenografts, and 43% +/- 3.5% and 14% +/- 3.0% for isolated mitral xenografts. Freedom from structural valve degeneration was 87% +/- 1.3% and 63% +/- 2.5% for all patients at 10 and 15 years, respectively, 86% +/- 2.7% and 58% +/- 4.1% for aortic homografts, 93% +/- 1.8% and 76% +/- 5.1% for aortic xenografts, and 75% +/- 4.0% and 47% +/- 7.4% for mitral xenografts. Of the 110 remaining patients, echocardiography was performed in 61 patients (23 aortic xenograft, 24 aortic homograft, 9 mitral xenograft, and 5 tricuspid xenograft) between 14 and 17 years after implantation. An early diastolic murmur was heard in 57% of all aortic valve replacements (AVRs) 62.5% of homograft AVRs, and 52% of xenograft AVRs. Echocardiographically, aortic regurgitation was detected in 79%, 83%, and 74% of all AVRs, homografts, and xenografts, respectively. Aortic stenosis was present clinically in 11% of all AVRs, 4% of homograft AVRs, and 17% of xenograft AVRs.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7646161     DOI: 10.1016/0003-4975(95)00220-f

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Comparative study of the mechanical behaviour of a cyanoacrylate and a bioadhesive.

Authors:  J M García Páez; E Jorge Herrero; A Rocha; M Maestro; J L Castillo-Olivares; I Millan; A Carrera Sanmartin; A Cordon
Journal:  J Mater Sci Mater Med       Date:  2004-02       Impact factor: 3.896

2.  Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior.

Authors:  J M García Páez; E Jorge Herrero; M Martín Maestro; A Rocha; B Arenaz; J L Castillo-Olivares; A Carrera Sanmartín; A Cordon; I Millán
Journal:  J Mater Sci Mater Med       Date:  2003-05       Impact factor: 3.896

3.  Mechanical effects of increases in the load applied in uniaxial and biaxial tensile testing: Part I. Calf pericardium.

Authors:  J M García Páez; E Jorge; A Rocha; M Maestro; J L Castillo-Olivares; I Millan; A Carrera; A Cordon; G Tellez; R Burgos
Journal:  J Mater Sci Mater Med       Date:  2002-04       Impact factor: 3.896

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.