Literature DB >> 15348911

Analysis of shearing stress in the limited durability of bovine pericardium used as a biomaterial.

A Carrera San Martin1, J M García Paez, J V García Sestafe, E J Herrero, R Navidad, A Cordón, J L Castillo-Olivares.   

Abstract

The objective of the study was to determine the shearing stress exerted by the suture thread under conditions of normal working stress. Thirty-six samples of calf pericardium, similar to that employed in the manufacture of bioprosthetic cardiac valve leaflets, were subjected to tensile testing. Prior to the trial, a continuous suture was sewn in the central zone of each sample, at a 45 degrees angle to the longest axis of the sample, using commercially-available threads (silk, Gore-Tex, Surgilene and nylon). Application of the Mohr circle for combined wear revealed that the shearing stress ranged between 2.68-fold greater (for samples sewn with silk) and 5.48-fold greater (for samples sewn with nylon) than the working tensile stress in the region of the suture. It is concluded that the shearing stress is responsible for the limited durability of sutured samples of calf pericardium prepared to simulate bioprosthetic cardiac valve leaflets. Copyright 1998 Chapman & Hall

Entities:  

Year:  1998        PMID: 15348911     DOI: 10.1023/a:1008842914029

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  19 in total

1.  Durability of glutaraldehyde-fixed pericardial valve prostheses: clinical and animal experimental studies.

Authors:  M Valente; M Minarini; P Ius; E Talenti; U Bortolotti; A Milano; G Thiene
Journal:  J Heart Valve Dis       Date:  1992-11

2.  Is cutting stress responsible for the limited durability of heart valve bioprostheses?

Authors:  J M García Paez; A Carrera San Martín; J V García Sestafe; I Millán; E Jorge; I Candela; J L Castillo-Olivares
Journal:  J Thorac Cardiovasc Surg       Date:  1990-10       Impact factor: 5.209

3.  Ionescu-Shiley bovine pericardial bioprostheses. Histologic and ultrastructural studies.

Authors:  S L Hilbert; V J Ferrans; H A McAllister; D A Cooley
Journal:  Am J Pathol       Date:  1992-05       Impact factor: 4.307

4.  Tensile properties of suture materials.

Authors:  J A von Fraunhofer; R J Storey; B J Masterson
Journal:  Biomaterials       Date:  1988-07       Impact factor: 12.479

5.  Characterization of the mechanics of human ortic and mitral valve leaflets.

Authors:  R E Clark; G A Butterworth
Journal:  Surg Forum       Date:  1971

6.  Tensile strength and knot security of surgical suture materials.

Authors:  J B Herrmann
Journal:  Am Surg       Date:  1971-04       Impact factor: 0.688

7.  Tensile strength of suture materials.

Authors:  J A von Fraunhofer; R S Storey; I K Stone; B J Masterson
Journal:  J Biomed Mater Res       Date:  1985 May-Jun

Review 8.  Modern cardiac valve devices--bioprostheses and mechanical prostheses: state of the art.

Authors:  W R Jamieson
Journal:  J Card Surg       Date:  1993-01       Impact factor: 1.620

9.  Inhibition of calcification of glutaraldehyde pretreated porcine aortic valve cusps with sodium dodecyl sulfate: preincubation and controlled release studies.

Authors:  D Hirsch; J Drader; T J Thomas; F J Schoen; J T Levy; R J Levy
Journal:  J Biomed Mater Res       Date:  1993-12

10.  Study of the calcification of bovine pericardium: analysis of the implication of lipids and proteoglycans.

Authors:  E Jorge-Herrero; P Fernández; M Gutiérrez; J L Castillo-Olivares
Journal:  Biomaterials       Date:  1991-09       Impact factor: 12.479

View more
  3 in total

1.  Comparative study of the mechanical behaviour of a cyanoacrylate and a bioadhesive.

Authors:  J M García Páez; E Jorge Herrero; A Rocha; M Maestro; J L Castillo-Olivares; I Millan; A Carrera Sanmartin; A Cordon
Journal:  J Mater Sci Mater Med       Date:  2004-02       Impact factor: 3.896

2.  Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior.

Authors:  J M García Páez; E Jorge Herrero; M Martín Maestro; A Rocha; B Arenaz; J L Castillo-Olivares; A Carrera Sanmartín; A Cordon; I Millán
Journal:  J Mater Sci Mater Med       Date:  2003-05       Impact factor: 3.896

3.  On the mechanical properties of bovine serum albumin (BSA) adhesives.

Authors:  N S Berchane; M J Andrews; S Kerr; N K H Slater; F F Jebrail
Journal:  J Mater Sci Mater Med       Date:  2008-01-16       Impact factor: 3.896

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.