Is cutting stress responsible for the limited durability of heart valve bioprostheses?

J M García Paez1, A Carrera San Martín, J V García Sestafe, I Millán, E Jorge, I Candela, J L Castillo-Olivares.   

Abstract

The limited durability of the valve bioprostheses made from calf pericardium is partially due to the calcification of this biomaterial and to mechanical fatigue of the tissue. The object of this study is to determine the harmful effect on the pericardial membrane of cutting caused by the suture thread by showing the different elastic behaviors of the biomaterials employed. This cutting stress is established during the process of molding the valve leaflet, creating a vulnerable point from the very moment of construction, which is an important factor in the limited duration of the bioprosthesis.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2214834

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  7 in total

1.  Comparative study of the mechanical behaviour of a cyanoacrylate and a bioadhesive.

Authors:  J M García Páez; E Jorge Herrero; A Rocha; M Maestro; J L Castillo-Olivares; I Millan; A Carrera Sanmartin; A Cordon
Journal:  J Mater Sci Mater Med       Date:  2004-02       Impact factor: 3.896

2.  Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior.

Authors:  J M García Páez; E Jorge Herrero; M Martín Maestro; A Rocha; B Arenaz; J L Castillo-Olivares; A Carrera Sanmartín; A Cordon; I Millán
Journal:  J Mater Sci Mater Med       Date:  2003-05       Impact factor: 3.896

3.  Porcine pericardial membrane subjected to tensile testing: preliminary study of the process of selecting tissue for use in the construction of cardiac bioprostheses.

Authors:  J M Garcia Páez; E Jorge-Herrero; A Carrera; I Millán; A Rocha; J Salvador; J Mendez; G Téllez; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2001-05       Impact factor: 3.896

4.  Mechanical effects of increases in the load applied in uniaxial and biaxial tensile testing. Part II. Porcine pericardium.

Authors:  J M García Páez; E Jorge; A Rocha; J L Castillo-Olivares; I Millan; A Carrera; A Cordon; G Tellez; R Burgos
Journal:  J Mater Sci Mater Med       Date:  2002-05       Impact factor: 3.896

5.  The influence of chemical treatment and suture on the elastic behavior of calf pericardium utilized in the construction of cardiac bioprostheses.

Authors:  J M García Páez; E J Herrero; A Carrera San Martín; J V García Sestafe; G Téllez; I Millán; J Salvador; A Cordón; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2000-05       Impact factor: 3.896

6.  The influence of chemical treatment and suture on the elastic behavior of calf pericardium utilized in the construction of cardiac bioprostheses.

Authors:  J M García Páez; E J Herrero; A Carrera San Martín; J V García Sestafe; G Téllez; I Millán; J Salvador; A Cordón; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2000-07       Impact factor: 3.896

7.  Analysis of shearing stress in the limited durability of bovine pericardium used as a biomaterial.

Authors:  A Carrera San Martin; J M García Paez; J V García Sestafe; E J Herrero; R Navidad; A Cordón; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  1998-02       Impact factor: 3.896

  7 in total