Literature DB >> 1742413

Study of the calcification of bovine pericardium: analysis of the implication of lipids and proteoglycans.

E Jorge-Herrero1, P Fernández, M Gutiérrez, J L Castillo-Olivares.   

Abstract

A major problem with cardiac bioprosthesis is the calcification of the tissue used in their manufacture, an event which may be promoted by multiple factors. A subcutaneously implanted model was used to determine, by selective extractions of proteoglycans and lipids, the role played by these compounds in the calcification of the bovine pericardial tissue used in the construction of some biological valves. The selective extraction of proteoglycans resulted in a great accumulation of calcium salts in the tissue, which, moreover, had a reduced hydrothermal stability. On the other hand, lipid extraction produced no modification in the stability of the tissue and resulted in a lesser calcium accumulation than in the control group. Proteoglycans and lipids may, therefore, be implicated in mineralization of the pericardial tissue.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1742413     DOI: 10.1016/0142-9612(91)90117-s

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  18 in total

1.  Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior.

Authors:  J M García Páez; E Jorge Herrero; M Martín Maestro; A Rocha; B Arenaz; J L Castillo-Olivares; A Carrera Sanmartín; A Cordon; I Millán
Journal:  J Mater Sci Mater Med       Date:  2003-05       Impact factor: 3.896

2.  A new method for selecting calf pericardium for use in cardiac bioprostheses on the basis of morphological and mechanical criteria.

Authors:  J M García Páez; E Jorge-Herrero; A Carrera; I Millán; A Rocha; A Cordón; J Salvador; N Sainz; J Méndez; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2001-08       Impact factor: 3.896

3.  Porcine pericardial membrane subjected to tensile testing: preliminary study of the process of selecting tissue for use in the construction of cardiac bioprostheses.

Authors:  J M Garcia Páez; E Jorge-Herrero; A Carrera; I Millán; A Rocha; J Salvador; J Mendez; G Téllez; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2001-05       Impact factor: 3.896

4.  Exogenous hyaluronic acid and chondroitin sulfate crosslinking treatment for increasing the amount and stability of glycosaminoglycans in bioprosthetic heart valves.

Authors:  Yang Lei; Qinggong Ning; Yuyang Tang; Yunbing Wang
Journal:  J Mater Sci Mater Med       Date:  2019-03-06       Impact factor: 3.896

5.  Stability and function of glycosaminoglycans in porcine bioprosthetic heart valves.

Authors:  Joshua J Lovekamp; Dan T Simionescu; Jeremy J Mercuri; Brett Zubiate; Michael S Sacks; Narendra R Vyavahare
Journal:  Biomaterials       Date:  2005-09-06       Impact factor: 12.479

Review 6.  Small Diameter Xenogeneic Extracellular Matrix Scaffolds for Vascular Applications.

Authors:  Manuela Lopera Higuita; Leigh G Griffiths
Journal:  Tissue Eng Part B Rev       Date:  2019-11-27       Impact factor: 6.389

7.  Calcification and identification of metalloproteinases in bovine pericardium after subcutaneous implantation in rats.

Authors:  E Jorge-Herrero; J Turnay; P Calero; N Olmo; I López De Silanes; M Martín Maestro; M A Lizarbe; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

8.  The influence of chemical treatment and suture on the elastic behavior of calf pericardium utilized in the construction of cardiac bioprostheses.

Authors:  J M García Páez; E J Herrero; A Carrera San Martín; J V García Sestafe; G Téllez; I Millán; J Salvador; A Cordón; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2000-05       Impact factor: 3.896

9.  The influence of chemical treatment and suture on the elastic behavior of calf pericardium utilized in the construction of cardiac bioprostheses.

Authors:  J M García Páez; E J Herrero; A Carrera San Martín; J V García Sestafe; G Téllez; I Millán; J Salvador; A Cordón; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2000-07       Impact factor: 3.896

10.  Analysis of shearing stress in the limited durability of bovine pericardium used as a biomaterial.

Authors:  A Carrera San Martin; J M García Paez; J V García Sestafe; E J Herrero; R Navidad; A Cordón; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  1998-02       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.