A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE.

A A Besong1, J L Hailey, E Ingham, M Stone, B M Wroblewski, J Fisher.   

Abstract

Damage to polished femoral heads in vivo can cause increased wear of acetabular cups. Oxidation and ageing after sterilisation by gamma irradiation in air, can also change the mechanical properties and wear resistance of ultra high molecular weight polyethylene (UHMWPE). This study investigated the combined effect of these changes in material properties on the wear of UHMWPE for different counterface roughnesses, representative of new femoral heads and those damaged in vivo. Wear rates were studied on a tri-pin-on-disc tribometer in a protein-containing solution. A comparison was made of the wear, using three different counterface roughnesses, of specimens that were manufactured from polyethylene acetabular cups of different shelf ages (3-120 months) after gamma irradiation in air but never implanted. These were compared to the wear of control specimens that were manufactured from cups that had not been sterilised. The wear surfaces were tested 1 mm below the initial articulating surface of the cup, the position of high degradation. The wear rate of UHMWPE which had been sterilised by gamma irradiation in air was shown to increase significantly with ageing time on the shelf for all counterface conditions. The wear rate of all materials increased markedly as the counterface roughness increased, but to different extents depending on the age of the material. The combined effect of ageing and increase in counterface roughness had a dramatic effect (as high as 2000 fold increase) on the wear rate. Both ageing of the polymer and damage to the femoral head have been cited as causing increased wear in vivo. The results of this study demonstrate that these variables can act synergistically to markedly effect UHMWPE wear rate.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9171903

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  8 in total

1.  Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene.

Authors:  H Marrs; D C Barton; R A Jones; I M Ward; J Fisher; C Doyle
Journal:  J Mater Sci Mater Med       Date:  1999-06       Impact factor: 3.896

2.  Long-term radiographic assessment of cemented polyethylene acetabular cups.

Authors:  Sophie Williams; Graham Isaac; Neil Porter; John Fisher; John Older
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

3.  [Selective laser sintering and performances of porous titanium implants].

Authors:  Ting Wei; Xin-Wei Zhang; Hui-Qiang Sun; Meng-Yun Mao
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2018-10-01

4.  The effect of accelerated aging on the wear of UHMWPE.

Authors:  H Sakoda; J Fisher; S Lu; F Buchanan
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

5.  Can pin-on-disk testing be used to assess the wear performance of retrieved UHMWPE components for total joint arthroplasty?

Authors:  Steven M Kurtz; Daniel W MacDonald; Sevi Kocagöz; Mariya Tohfafarosh; Doruk Baykal
Journal:  Biomed Res Int       Date:  2014-09-11       Impact factor: 3.411

6.  An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements.

Authors:  O O'Dwyer Lancaster-Jones; S Williams; L M Jennings; J Thompson; G H Isaac; J Fisher; M Al-Hajjar
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-09-23       Impact factor: 3.368

7.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24

8.  Microstructural modifications induced by accelerated aging and lipid absorption in remelted and annealed UHMWPEs for total hip arthroplasty.

Authors:  Leonardo Puppulin; Wenliang Zhu; Nobuhiko Sugano; Giuseppe Pezzotti
Journal:  J Biomater Appl       Date:  2014-08-31       Impact factor: 2.646

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.