Literature DB >> 15330021

Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol).

S K Chauhan1, G W Clark, S Lloyd, R G Scott, W Breidahl, J M Sikorski.   

Abstract

A controlled study, comparing computer- and conventional jig-assisted total knee replacement in six cadavers is presented. In order to provide a quantitative assessment of the alignment of the replacements, a CT-based technique which measures seven parameters of alignment has been devised and used. In this a multi-slice CT machine scanned in 2.5 mm slices from the acetabular roof to the dome of the talus with the subject's legs held in a standard position. The mechanical and anatomical axes were identified, from three-dimensional landmarks, in both anteroposterior and lateral planes. The coronal and sagittal alignment of the prosthesis was then measured against the axes. The rotation of the femoral component was measured relative to the transepicondylar axis. The rotation of the tibial component was measured with reference to the posterior tibial condyles and the tibial tuberosity. Coupled femorotibial rotational alignment was assessed by superimposition of the femoral and tibial axial images. The radiation dose was 2.7 mSV. The computer-assisted total knee replacements showed better alignment in rotation and flexion of the femoral component, the posterior slope of the tibial component and in the matching of the femoral and tibial components in rotation. Differences were statistically significant and of a magnitude that support extension of computer assistance to the clinical situation.

Mesh:

Year:  2004        PMID: 15330021     DOI: 10.1302/0301-620x.86b6.15456

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  75 in total

1.  No influence of femoral component rotation by the lateral femoral posterior condylar cartilage remnant technique on clinical outcomes in navigation-assisted TKA.

Authors:  Seong Hwan Kim; Yong-Beom Park; Dae Woong Ham; Jae-Sung Lee; Min-Ku Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-02       Impact factor: 4.342

2.  Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device.

Authors:  Ramon Gheno; Eric Nectoux; Bernard Herbaux; Matteo Baldisserotto; Luiz Glock; Anne Cotten; Nathalie Boutry
Journal:  Eur Radiol       Date:  2011-10-20       Impact factor: 5.315

3.  Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty.

Authors:  Stephen M Howell; Justin Chen; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-05       Impact factor: 4.342

4.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

5.  Three-dimensional analysis of image-free navigation system for total knee arthroplasty.

Authors:  D Tigani; E Rimondi; P Trentani; M Ansaloni; L Amendola; D Testi
Journal:  Musculoskelet Surg       Date:  2010-12-29

6.  [Computer-assisted surgery-(CAS-)guided correction arthrodesis of the subtalar joint].

Authors:  Martinus Richter
Journal:  Oper Orthop Traumatol       Date:  2010-10       Impact factor: 1.154

7.  Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Alfonso Noriega-Fernandez; Jose Manuel Fernandez-Carreira; Jose Manuel Fernandez-Simon; Jimena Llorens de los Rios
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

8.  Evaluation of anatomic references for tibial sagittal alignment in total knee arthroplasty.

Authors:  Hyuk Soo Han; Chong Bum Chang; Sang Cheol Seong; Sahnghoon Lee; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-02-13       Impact factor: 4.342

9.  Improved design decreases wear in total knee arthroplasty with varus malalignment.

Authors:  Kazutaka Nishikawa; Ken Okazaki; Shuichi Matsuda; Yasutaka Tashiro; Shinya Kawahara; Hiroyuki Nakahara; Shigetoshi Okamoto; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-16       Impact factor: 4.342

10.  Comparision of blood loss between computer assisted and conventional total knee arthroplasty.

Authors:  Paras Kumar Mohanlal; Nemandra Sandiford; John A Skinner; Sr Samsani
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.