Literature DB >> 25155048

Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty.

Daniel Hernandez-Vaquero1, Alfonso Noriega-Fernandez, Jose Manuel Fernandez-Carreira, Jose Manuel Fernandez-Simon, Jimena Llorens de los Rios.   

Abstract

PURPOSE: Computer-assisted surgery (CAS) may facilitate better positioning of total knee arthroplasty (TKA) along the coronal and lateral axes; however, there are doubts as to its usefulness in the rotational plane.
METHODS: This is a prospective study of 95 TKAs comparing two groups: the CAS group and the standard equipment group. The series comprises 95 cases. A radiography of the lower limb and computer tomographies (CTs) of the femoral condylar region, the proximal end of the tibia and the ankle were performed to measure rotational angulation. A month after TKA surgery, the radiography and the CTs were repeated to analyze the position of the prosthetic components in the rotational plane.
RESULTS: In the coronal axis, both CAS and mechanical technique improved femoro-tibial alignment, but when there are preexisting deformities ≥4°, CAS obtains better results. A strong correlation (R = 0.94, p = 0.001) was observed between the mean rotational axis measured with CT in the tibial plateau and that measured from the axis of the ankle. The mean initial femoral rotation of the complete series was 6.7° and 2.7° at 1-month follow-up (p < 0.001). In the standard instrumentation group, the femoral rotation went from 6.8° to 2.3°, whereas in the CAS group the femoral rotation went from 6.5° to 3.1° (p = 0.039), which is very close to the ideal 3° angle of external rotation. Tibial rotation changed by 5.28° for the entire patient population, but no differences were found when comparing CAS and standard instrumentation.
CONCLUSION: CAS improves frontal alignment in TKA, especially in the presence of preoperative deformities. In the femoral component, navigation most closely replicated the ideal 3° external rotation of the femoral component, but tibial rotation did not differ when comparing CAS to standard instrumentation. LEVEL OF EVIDENCE: II.

Entities:  

Mesh:

Year:  2014        PMID: 25155048     DOI: 10.1007/s00167-014-3233-9

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  36 in total

1.  Anatomic rotational relationships of the proximal tibia, distal femur, and patella: implications for rotational alignment in total knee arthroplasty.

Authors:  Stephen J Incavo; Kathryn M Coughlin; Charles Pappas; Bruce D Beynnon
Journal:  J Arthroplasty       Date:  2003-08       Impact factor: 4.757

2.  Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri
Journal:  Acta Orthop Scand       Date:  2004-02

3.  Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.

Authors:  Young-Wan Moon; Chul-Won Ha; Kwan-Hong Do; Chang-Young Kim; Jeong-Hoon Han; Sang-Eun Na; Choong-Hee Lee; Jae-Gyoon Kim; Youn-Soo Park
Journal:  Comput Aided Surg       Date:  2012

4.  Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty.

Authors:  W P Yau; Anthony Leung; K G Liu; C H Yan; Lisa L S Wong; K Y Chiu
Journal:  J Arthroplasty       Date:  2007-12       Impact factor: 4.757

5.  Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis.

Authors:  Paolo Aglietti; Lorenzo Sensi; Pierluigi Cuomo; Antonio Ciardullo
Journal:  Clin Orthop Relat Res       Date:  2008-09-30       Impact factor: 4.176

6.  The variability of femoral rotational alignment in total knee arthroplasty.

Authors:  Robert A Siston; Jay J Patel; Stuart B Goodman; Scott L Delp; Nicholas J Giori
Journal:  J Bone Joint Surg Am       Date:  2005-10       Impact factor: 5.284

Review 7.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

Review 8.  Rotational alignment of the distal femur: a literature review.

Authors:  J Victor
Journal:  Orthop Traumatol Surg Res       Date:  2009-07-09       Impact factor: 2.256

9.  Can computer assistance improve the clinical and functional scores in total knee arthroplasty?

Authors:  Daniel Hernández-Vaquero; Abelardo Suarez-Vazquez; Susana Iglesias-Fernandez
Journal:  Clin Orthop Relat Res       Date:  2011-08-27       Impact factor: 4.176

10.  Accurate alignment and high function after kinematically aligned TKA performed with generic instruments.

Authors:  Stephen M Howell; Stelios Papadopoulos; Kyle T Kuznik; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

View more
  17 in total

1.  Influence of tibial rotation in total knee arthroplasty on knee kinematics and retropatellar pressure: an in vitro study.

Authors:  Arnd Steinbrück; Christian Schröder; Matthias Woiczinski; Tatjana Müller; Peter E Müller; Volkmar Jansson; Andreas Fottner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-11       Impact factor: 4.342

2.  Tibiofemoral rotational alignment affects flexion angles in navigated posterior-stabilized total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Akihiko Toda; Shinya Oka; Kazuki Kodato; Koji Takayama; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

3.  No correlation between rotation of femoral components in the transverse plane and clinical outcome after total knee arthroplasty.

Authors:  Roland Becker; Katharina Bäker; Hagen Hommel; Manfred Bernard; Sebastian Kopf
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-16       Impact factor: 4.342

Review 4.  Optimizing Intraoperative Blood Management for One-Stage Bilateral Total Knee Arthroplasty.

Authors:  Vasileios Soranoglou; Lazaros A Poultsides; Georgios K Triantafyllopoulos; Ivan De Martino; Stavros G Memtsoudis; Thomas P Sculco
Journal:  HSS J       Date:  2017-12-07

5.  [Progress in the method of tibial prosthesis rotation alignment in total knee arthroplasty].

Authors:  Xin Liu; Shengjie Guo; Shuaijie Li; Yanwei Cao; Chuan Xiang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-09-15

6.  Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.

Authors:  Reha N Tandogan; Nanne P Kort; Ersin Ercin; Floris van Rooij; Luca Nover; Mo Saffarini; Michael T Hirschmann; Roland Becker; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-03-01       Impact factor: 4.114

7.  Total knee replacement modifies the preoperative tibial torsion angle-similar results between computer-assisted and standard technique.

Authors:  Daniel Hernandez-Vaquero; Alfonso Noriega-Fernandez; Sergio Roncero-Gonzalez; Andres A Sierra-Pereira; Manuel A Sandoval-Garcia
Journal:  Ann Transl Med       Date:  2018-04

8.  Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty.

Authors:  Shih-Jie Lin; Chien-Ying Lee; Kuo-Chin Huang; Kuo-Ti Peng; Tsan-Wen Huang; Mel S Lee; Robert Wen-Wei Hsu; Wun-Jer Shen
Journal:  J Orthop Surg Res       Date:  2015-09-02       Impact factor: 2.359

9.  Tibial component rotation in total knee arthroplasty.

Authors:  Peter Z Feczko; Bart G Pijls; Michael J van Steijn; Lodewijk W van Rhijn; Jacobus J Arts; Peter J Emans
Journal:  BMC Musculoskelet Disord       Date:  2016-02-16       Impact factor: 2.362

10.  Computer-assisted total knee arthroplasty using mini midvastus or medial parapatellar approach technique: A prospective, randomized, international multicentre trial.

Authors:  Peter Feczko; Lutz Engelmann; Jacobus J Arts; David Campbell
Journal:  BMC Musculoskelet Disord       Date:  2016-01-13       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.