Abstract

BACKGROUND: Bleeding during total knee arthroplasty (TKA) can cause significant morbidity and mortality. One proposed benefit of computer assisted TKA is decreased bleeding as the femoral canal is not invaded. This study assessed blood loss between computer assisted surgery (CAS) and conventional TKA.
MATERIALS AND METHODS: 73 consecutive patients (37 males, 36 females) underwent primary TKA between 2006 and 2009. Thirty eight patients underwent navigated TKA and 35 underwent conventional TKA for symptomatic osteoarthritis of the knee. These patients were matched for age, gender, and body mass index (BMI). Average age was 70.3 years (range 47-91 years). Mean BMI was 30 (range 17-49). Average preoperative hemoglobin was 13.26 g/dL (range 8.7-18.4 g/dL) in the navigated group and 13.47 g/dL (range 9.6-15.8 g/dL) in the conventional group (P = 0.9). Average tourniquet time was 110 min (range 90-150 min) in the navigated group and 96.7 min (range 60-145 min) in the conventional group (P = 0.77).
RESULTS: Average postoperative hemoglobin in the navigated group was 10.34 g/dL (range 7.5-14.8 g/dL) and in the conventional group was 10.03 g/dL (range 7.5-12.2 g/dL) (P = 0.17). Six patients in both groups required blood transfusions. The mean drain collection was 599 mL (range 150-1370 mL) in the navigated group and 562 mL (range 750-1000 mL) in the conventional group (P = 0.1724). These results suggest that there is no significant reduction in blood loss in CAS TKA.
CONCLUSION: These results suggest that there is no significant difference in blood loss in CAS TKA and conventional TKA. This study also highlights the heterogeneity of methods used in studies related to CAS TKA. We believe that there is a need for a large multicenter prospective randomized controlled trial to be performed before a consensus can be reached on the influence of CAS techniques on blood loss during primary TKA.

Entities:  

Keywords:  Blood loss; computer navigated total knee arthroplasty; conventional total knee arthroplasty

Year:  2013        PMID: 23532765      PMCID: PMC3601237          DOI: 10.4103/0019-5413.106906

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


  18 in total

1.  Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss.

Authors:  N Kumar; J Saleh; E Gardiner; V G Devadoss; F R Howell
Journal:  J Arthroplasty       Date:  2000-10       Impact factor: 4.757

Review 2.  A direct antifibrinolytic agent in major orthopedic surgery.

Authors:  Charles Marc Samama
Journal:  Orthopedics       Date:  2004-06       Impact factor: 1.390

3.  Blood loss after total knee replacement: effects of computer-assisted surgery.

Authors:  Y Kalairajah; D Simpson; A J Cossey; G M Verrall; A J Spriggins
Journal:  J Bone Joint Surg Br       Date:  2005-11

4.  Effect of drain pressure in total knee arthroplasty.

Authors:  K W Cheung; K H Chiu
Journal:  J Orthop Surg (Hong Kong)       Date:  2006-08       Impact factor: 1.118

5.  Complications associated with warfarin prophylaxis in total knee arthroplasty.

Authors:  C J Sutherland; J R Schurman
Journal:  Clin Orthop Relat Res       Date:  1987-06       Impact factor: 4.176

6.  Incidence and risk factors for allogenic blood transfusion during major joint replacement using an integrated autotransfusion regimen. The Rizzoli Study Group on Orthopaedic Anaesthesia.

Authors:  B Borghi; A Casati
Journal:  Eur J Anaesthesiol       Date:  2000-07       Impact factor: 4.330

7.  Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique.

Authors:  F Conteduca; F Massai; R Iorio; E Zanzotto; D Luzon; A Ferretti
Journal:  Int Orthop       Date:  2008-09-02       Impact factor: 3.075

8.  Blood loss after total knee replacement. Effects of tourniquet release and continuous passive motion.

Authors:  P A Lotke; V J Faralli; E M Orenstein; M L Ecker
Journal:  J Bone Joint Surg Am       Date:  1991-08       Impact factor: 5.284

9.  Predictors of transfusion risk in elective knee surgery.

Authors:  E M Keating; J B Meding; P M Faris; M A Ritter
Journal:  Clin Orthop Relat Res       Date:  1998-12       Impact factor: 4.176

10.  Minimal incision total knee arthroplasty: early experience.

Authors:  Alfred J Tria; Thomas M Coon
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

View more
  6 in total

1.  Computer navigation is effective in reducing blood loss but has no effect on transfusion requirement following primary total knee arthroplasty: a meta-analysis.

Authors:  Seung-Beom Han; Hyun-Jung Kim; Tae-Kyun Kim; Yong In; Kwang-Jun Oh; In-Jun Koh; Dae-Hee Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-27       Impact factor: 4.342

2.  Is TKA with computer-assisted navigation associated with less blood loss? A comparative study between computer-navigated and conventional method.

Authors:  Diamantis Mitsiou; Emilios E Pakos; Dimitrios V Papadopoulos; Giorgos Georgiadis; Ioannis D Gelalis; Andreas G Tsantes; Ioannis Gkiatas; Nikos Kalos; Theodoros A Xenakis
Journal:  J Orthop       Date:  2020-01-13

3.  The use of patient-specific instruments does not reduce blood loss during minimally invasive total knee arthroplasty?

Authors:  Emmanuel Thienpont; Irina Grosu; Frederic Paternostre; Pierre-Emmanuel Schwab; Jean Cyr Yombi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-27       Impact factor: 4.342

4.  Use of patient-specific cutting blocks reduces blood loss after total knee arthroplasty.

Authors:  Vicente J León; María A Lengua; Víctor Calvo; Alonso J Lisón
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-12-20

5.  Indian Journal of Orthopaedics: Journey continues.

Authors:  Anil K Jain; Sudhir Kumar
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

6.  A Randomized Controlled Study to Compare the Total and Hidden Blood Loss in Computer-Assisted Surgery and Conventional Surgical Technique of Total Knee Replacement.

Authors:  Amit Singla; Rajesh Malhotra; Vijay Kumar; Chandra Lekha; G Karthikeyan; Vishwas Malik
Journal:  Clin Orthop Surg       Date:  2015-05-18
  6 in total