Literature DB >> 15307390

Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses.

Roberto Bellucci1, Simonetta Morselli, Patricia Piers.   

Abstract

PURPOSE: We compared corneal and total higher order wavefront aberrations in 25 pseudophakic eyes implanted with five different types of intraocular lenses to obtain an objective evaluation of the optical quality of these pseudophakic eyes. Five IOLs per type were studied.
METHODS: Implanted lenses were the Pharmacia Tecnis Z9000 with negative spherical aberration, Pharmacia 911 Edge, Alcon Acrysof SA60AT and MA60BM, and Allergan Sensar AR40e. Eyes were examined using the Topcon KR-9000PW topographer/aberrometer, which obtains simultaneous coaxial measurements of corneal and ocular aberrations, and displays the calculated Point Spread Function (PSF) and Modulation Transfer Function (MTF).
RESULTS: Corneal spherical aberration was positive in all tested eyes. For a 4-mm optical zone, ocular spherical aberration was 0.0054+/-0.0172 microm root-mean-square (RMS) in eyes implanted with the Tecnis lens, and was 0.0562 to 0.0974 microm RMS in eyes implanted with the four other conventional IOLs. A myopic refractive shift with mydriasis of -0.08 D occurred with the Tecnis IOL; it was -0.57 to -0.90 D with the conventional IOLs. Coma did not show a substantial reduction with any of the IOLs. Total wavefront aberrations showed nonsignificant reduction with the Tecnis lens. The PSF and the MTF also showed nonsignificant improvements over conventional IOLs.
CONCLUSIONS: The optical quality of pseudophakic eyes can be measured in vivo by aberrometers. Different IOLs resulted in measurably different outcomes. In this preliminary study, compensation of the spherical aberration observed with the Tecnis lens confirmed the theoretical predictions associated with this lens and resulted in no myopic shift in refraction with mydriasis.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15307390     DOI: 10.3928/1081-597X-20040701-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  18 in total

1.  Star testing: a novel evaluation of intraocular lens optical quality.

Authors:  L Mitchell; A C B Molteno; T H Bevin; G Sanderson
Journal:  Br J Ophthalmol       Date:  2006-05       Impact factor: 4.638

2.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

3.  [The aspheric blue light filter IOL AcrySof IQ compared to the AcrySof SA60AT : influence of IOL power, pupil diameter, and corneal asphericity on postoperative spherical aberration].

Authors:  U Mester; H Kaymak
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

4.  Corneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery.

Authors:  Tarfah M Al-Sayyari; Samah M Fawzy; Ahmed A Al-Saleh
Journal:  Saudi J Ophthalmol       Date:  2014-06-25

5.  Comparative study of visual function and ocular aberrations of two different one-piece designed hydrophilic acrylic intraocular lens.

Authors:  Yuxin Zhao; Zhaoxia Wang; Xia Tian; Xuehong Wang; Xining Gao
Journal:  Int Ophthalmol       Date:  2017-05-30       Impact factor: 2.031

6.  Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration.

Authors:  T Oshika; G Sugita; K Miyata; T Tokunaga; T Samejima; C Okamoto; Y Ishii
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

7.  [Accuracy of lens power calculation and centration of an aspheric intraocular lens].

Authors:  K A Becker; M P Holzer; A J Reuland; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-10       Impact factor: 1.059

8.  Wavefront analysis and modulation transfer function of three multifocal intraocular lenses.

Authors:  Marcony R Santhiago; Marcelo V Netto; Jackson Barreto; Beatriz A F Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Indian J Ophthalmol       Date:  2010 Mar-Apr       Impact factor: 1.848

9.  A contralateral eye study comparing apodized diffractive and full diffractive lenses: wavefront analysis and distance and near uncorrected visual acuity.

Authors:  Marcony Rodrigues de Santhiago; Marcelo Vieira Netto; Jackson Barreto; Beatriz de Abreu Fiuza Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

10.  Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO.

Authors:  Ahmad-Reza Baghi; Mohammad-Reza Jafarinasab; Hossein Ziaei; Zahra Rahmani
Journal:  J Ophthalmic Vis Res       Date:  2008-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.