Literature DB >> 28560652

Comparative study of visual function and ocular aberrations of two different one-piece designed hydrophilic acrylic intraocular lens.

Yuxin Zhao1, Zhaoxia Wang2, Xia Tian2, Xuehong Wang2, Xining Gao2.   

Abstract

PURPOSE: To determine whether the aspherical IOL, Tecnis ZCB00, can improve the visual quality by measuring visual acuity, wavefront aberrations, and contrast sensitivity.
METHODS: It was a retrospective case series. Patients who underwent phacoemulsification cataract surgery were divided into two groups. One group (Group TC) was implanted with one-piece aspherical acrylic IOL (Tecnis ZCB00, AMO); the other (Group SA) was implanted with one-piece spherical acrylic IOL (Sensar AAB00, AMO). Eighty-eight eyes were selected into this study, among them 43 eyes in 26 male cases and 45 eyes in 29 female cases. Thirty-six eyes in 23 cases were in Group TC, and 52 eyes in 32 cases were in Group SA. Three months postoperatively, aberrations were analyzed with i-Trace visual function analyzer (Tracy Technologies, USA). Contrast sensitivities were measured with Takaci-CGT-1000 contrast glare tester (Seiko, Japan).
RESULTS: All the 88 eyes underwent phacoemulsification with intraocular lens implantation, without complications during or after surgery. Three months postoperatively, the uncorrected vision acuity in Group TC was significantly better than in Group SA (P = 0.007). At the pupil size of 5.0 mm, higher-order aberrations in Group TC were significantly higher than in Group SA (P = 0.02), especially the spherical aberration (Z 40 ) (P < 0.001); at the pupil size of 4.0 mm, Z 40 in Group SA was statistically higher than in Group TC (P < 0.001); at the pupil size of 3.0 mm, higher-order aberrations such as coma (Z 3-1,1 ) and trefoil aberration (Z 3-3,3 ) in Group SA were obviously higher than in Group TC (P = 0.01). In the low spatial frequency, the contrast sensitivity and the glare sensitivity in Group TC were significantly higher than in Group SA (P < 0.05).
CONCLUSIONS: By the short-term follow-up (3 months), the aspherical acrylic IOL can reduce the higher-order aberrations (especially the spherical aberration) and increase the contrast sensitivity to improve the visual performance.

Entities:  

Keywords:  Aberration; Acrylic; Aspherical; Contrast sensitivity; Intraocular lens

Mesh:

Year:  2017        PMID: 28560652     DOI: 10.1007/s10792-017-0578-3

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  41 in total

1.  Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing.

Authors:  E Moreno-Barriuso; J M Lloves; S Marcos; R Navarro; L Llorente; S Barbero
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-05       Impact factor: 4.799

2.  Correlation between posterior capsule opacification and visual function before and after Neodymium: YAG laser posterior capsulotomy.

Authors:  Ken Hayashi; Hideyuki Hayashi; Fuminori Nakao; Fumihiko Hayashi
Journal:  Am J Ophthalmol       Date:  2003-10       Impact factor: 5.258

3.  Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye.

Authors:  Li Wang; Douglas D Koch
Journal:  Arch Ophthalmol       Date:  2005-09

Review 4.  Calculation of intraocular lens power: a review.

Authors:  Thomas Olsen
Journal:  Acta Ophthalmol Scand       Date:  2007-04-02

5.  Impact of a modified optic design on visual function: clinical comparative study.

Authors:  Ulrich Mester; Patrick Dillinger; Nicola Anterist
Journal:  J Cataract Refract Surg       Date:  2003-04       Impact factor: 3.351

6.  Influence of intraocular lens optical design on high-order aberrations.

Authors:  Futoshi Taketani; Eiichi Yukawa; Toshiaki Yoshii; Yuuko Sugie; Yoshiaki Hara
Journal:  J Cataract Refract Surg       Date:  2005-05       Impact factor: 3.351

7.  Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations.

Authors:  Thomas Kasper; Jens Bühren; Thomas Kohnen
Journal:  J Cataract Refract Surg       Date:  2006-12       Impact factor: 3.351

8.  Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study.

Authors:  Wei-rong Chen; He-hua Ye; Yi-yong Qian; Wen-hui Yang; Zhi-hong Lin
Journal:  Chin Med J (Engl)       Date:  2006-11-05       Impact factor: 2.628

9.  Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter.

Authors:  Thomas Kasper; Jens Bühren; Thomas Kohnen
Journal:  J Cataract Refract Surg       Date:  2006-01       Impact factor: 3.351

10.  Aberration and contrast sensitivity comparison of aspherical and monofocal and multifocal intraocular lens eyes.

Authors:  Mingbing Zeng; Yizhi Liu; Xialin Liu; Zhaohui Yuan; Lixia Luo; Yuanlin Xia; Yangfa Zeng
Journal:  Clin Exp Ophthalmol       Date:  2007 May-Jun       Impact factor: 4.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.