Literature DB >> 15266083

Dose area product reference levels in dental panoramic radiology.

Christine E Tierris1, Emmanuel N Yakoumakis, George N Bramis, Evangelos Georgiou.   

Abstract

The purpose of this study was to measure DAP (Dose Area Product) values in panoramic radiology with the use of a DAP meter, to determine corresponding reference levels, and to compare DAP between panoramic and intraoral radiology. DAP was measured in 62 panoramic X-ray units for 3 types of exposure (male, female and child) and in 20 intraoral X-ray units of 50, 60 and 70 kVp. DAP reference levels were 117 mGy cm2, 97 mGy cm2 and 77 mGy cm2 for exposure of a male, female and child respectively. Results showed that DAP from a panoramic dental examination is approximately twice that from a single intraoral examination. DAP meter is a very convenient and easy to use tool for patient dosimetry and for the establishment of reference levels in dental panoramic radiology.

Entities:  

Mesh:

Year:  2004        PMID: 15266083     DOI: 10.1093/rpd/nch341

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  8 in total

1.  A preliminary study to determine the diagnostic reference level using dose-area product for limited-area cone beam CT.

Authors:  A Endo; T Katoh; S B Vasudeva; I Kobayashi; T Okano
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

2.  Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

Authors:  Lienard A Chang; Donald L Miller; Choonsik Lee; Dunstana R Melo; Daphnée Villoing; Vladimir Drozdovitch; Isabelle Thierry-Chef; Sarah J Winters; Michael Labrake; Charles F Myers; Hyeyeun Lim; Cari M Kitahara; Martha S Linet; Steven L Simon
Journal:  Health Phys       Date:  2017-12       Impact factor: 1.316

3.  Assessment of Regional Diagnostic Reference Levels in Dental Radiography in Tamil Nadu.

Authors:  Amal Jose; A Saravana Kumar; K N Govindarajan; Sunil Dutt Sharma
Journal:  J Med Phys       Date:  2022-03-31

4.  Dosimetry analysis of panoramic-imaging devices in different-sized phantoms.

Authors:  Muizz A Wahid; Ella Choi; David S MacDonald; Nancy L Ford
Journal:  J Appl Clin Med Phys       Date:  2017-02-25       Impact factor: 2.102

5.  Assessment of Adult Diagnostic Reference Levels for Panoramic Radiography in Tamil Nadu Region.

Authors:  Amal Jose; A Saravana Kumar; K N Govindarajan; B Devanand; N Elango
Journal:  J Med Phys       Date:  2019-12-11

6.  Assessment of Regional Pediatric Diagnostic Reference Levels for Panoramic Radiography Using Dose Area Product.

Authors:  Amal Jose; A Saravana Kumar; K N Govindarajan; P Manimaran
Journal:  J Med Phys       Date:  2020-10-13

7.  Diagnostic reference levels in intraoral dental radiography in Korea.

Authors:  Eun-Kyung Kim; Won-Jeong Han; Jin-Woo Choi; Yun-Hoa Jung; Suk-Ja Yoon; Jae-Seo Lee
Journal:  Imaging Sci Dent       Date:  2012-12-23

8.  Dosimetry of Occupational Radiation around Panoramic X-ray Apparatus.

Authors:  Pakravan A H; Aghamiri S M R; Bamdadian T; Gholami M; Moshfeghi M
Journal:  J Biomed Phys Eng       Date:  2019-10-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.