Literature DB >> 15226213

Acute improvement in global and regional left ventricular systolic function after percutaneous heart valve implantation in patients with symptomatic aortic stenosis.

Fabrice Bauer1, Hélène Eltchaninoff, Christophe Tron, Pierre-François Lesault, Carla Agatiello, Deborah Nercolini, Geneviève Derumeaux, Alain Cribier.   

Abstract

BACKGROUND: The newly developed percutaneous heart valve (PHV) implantation technique decreases transaortic pressure gradient in patients with aortic stenosis. PHV replacement effects on left ventricular (LV) global and regional systolic function are currently unknown. METHODS AND
RESULTS: Eight patients with severe aortic stenosis had 2D echocardiography at baseline and 24 hours after PHV implantation to evaluate changes in LV volume and LV ejection fraction. Regional function, ie, both peak systolic anterior and posterior wall tissue velocity, as well as strain and strain rate imaging, were measured by tissue Doppler imaging from a short-axis view. At 24 hours, a significant reduction in transaortic mean pressure gradient (from 46+/-15 to 8+/-3 mm Hg; P<0.0001) was accompanied by an increase in aortic valve area (from 0.59+/-0.11 to 1.69+/-0.11 cm2; P<0.0001). LV end-diastolic volume remained unchanged (102+/-36 to 101+/-12 mL; P=NS), whereas LV ejection fraction increased (48+/-18% to 57+/-12%; P<0.01). Improvement in posterior wall displacement (posterior wall tissue velocity increased from 2.2+/-0.5 to 4.4+/-1.0 cm/s(-1); P=0.0003) and deformation (strain rate imaging increased from 1.0+/-0.3 to 1.9+/-0.7 s(-1), P=0.009, and strain increased from 11+/-5% to 17+/-9%; P=0.02) were observed.
CONCLUSIONS: Immediately after PHV replacement, improvement of LV global and regional systolic function was evidenced by tissue Doppler imaging.

Entities:  

Mesh:

Year:  2004        PMID: 15226213     DOI: 10.1161/01.CIR.0000134961.36773.D6

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  26 in total

1.  The novel two-dimensional strain reflects improvement and remodeling of left-ventricular function better than conventional echocardiographic parameters after aortic valve repair in pediatric patients.

Authors:  Yaping Mi; Tanja Rädle-Hurst; Axel Rentzsch; Diana Aicher; Hans Joachim Schäfers; Hashim Abdul-Khaliq
Journal:  Pediatr Cardiol       Date:  2012-06-02       Impact factor: 1.655

2.  Percutaneous implantation of the CoreValve aortic valve prosthesis in patients at high risk or rejected for surgical valve replacement: Clinical evaluation and feasibility of the procedure in the first 30 patients in the AMC-UvA.

Authors:  J Baan; Z Y Yong; K T Koch; J P S Henriques; B J Bouma; S G de Hert; J van der Meulen; J G P Tijssen; J J Piek; B A J M de Mol
Journal:  Neth Heart J       Date:  2010-01       Impact factor: 2.380

Review 3.  New percutaneous treatments for valve disease.

Authors:  Louise Coats; Philipp Bonhoeffer
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

4.  Closed-bore XMR (CBXMR) systems for aortic valve replacement: x-ray tube imaging performance.

Authors:  John A Bracken; Philip Komljenovic; Prasheel V Lillaney; Rebecca Fahrig; J A Rowlands
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

5.  Closed bore XMR (CBXMR) systems for aortic valve replacement: active magnetic shielding of x-ray tubes.

Authors:  John A Bracken; Giovanni DeCrescenzo; Philip Komljenovic; Prasheel V Lillaney; Rebecca Fahrig; J A Rowlands
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

6.  Closed bore XMR (CBXMR) systems for aortic valve replacement: investigation of rotating-anode x-ray tube heat loadability.

Authors:  John A Bracken; Prasheel V Lillaney; Rebecca Fahrig; J A Rowlands
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

Review 7.  TAVI 2012: state of the art.

Authors:  Jochen Reinöhl; Constantin von Zur Mühlen; Martin Moser; Stefan Sorg; Christoph Bode; Manfred Zehender
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

Review 8.  Emerging role of echocardiographic strain/strain rate imaging and twist in systolic function evaluation and operative procedure in patients with aortic stenosis.

Authors:  Bin Wang; Haiyan Chen; Xianhong Shu; Tao Hong; Hao Lai; Chunsheng Wang; Leilei Cheng
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-05-03

Review 9.  Assessment of left ventricular function in aortic stenosis.

Authors:  Alper Ozkan; Samir Kapadia; Murat Tuzcu; Thomas H Marwick
Journal:  Nat Rev Cardiol       Date:  2011-06-14       Impact factor: 32.419

10.  Transcatheter aortic valve implantation in patients with severely reduced left ventricular systolic function: a single-center experience.

Authors:  Mohamed El-Mawardy; Nora Wübken-Kleinfeld; Bettina Schwarz; Ken Gordian; Björn Stöcker; Holger Sier; Ralph Toelg; Volker Geist; Ernst-Günther Kraatz; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Clin Res Cardiol       Date:  2014-03-11       Impact factor: 5.460

View more