Closed bore XMR (CBXMR) systems for aortic valve replacement: active magnetic shielding of x-ray tubes.

John A Bracken1, Giovanni DeCrescenzo, Philip Komljenovic, Prasheel V Lillaney, Rebecca Fahrig, J A Rowlands.   

Abstract

Hybrid closed bore x-ray/MRI systems are being developed to improve the safety and efficacy of percutaneous aortic valve replacement procedures by harnessing the complementary strengths of the x-ray and MRI modalities in a single interventional suite without requiring patient transfer between two rooms. These systems are composed of an x-ray C-arm in close proximity (approximately 1 m) to an MRI scanner. The MRI magnetic fringe field can cause the electron beam in the x-ray tube to deflect. The deflection causes the x-ray field of view to shift position on the detector receptacle. This could result in unnecessary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. Therefore, the electron beam deflection must be corrected. The authors developed an active magnetic shielding system that can correct for electron beam deflection to within an accuracy of 5% without truncating the field of view or increasing exposure to the patient. This system was able to automatically adjust to different field strengths as the external magnetic field acting on the x-ray tube was changed. Although a small torque was observed on the shielding coils of the active shielding system when they were placed in a magnetic field, this torque will not impact their performance if they are securely mounted on the x-ray tube and the C-arm. The heating of the coils of the shielding system for use in the clinic caused by electric current was found to be slow enough not to require a dedicated cooling system for one percutaneous aortic valve replacement procedure. However, a cooling system will be required if multiple procedures are performed in one session.

Entities:  

Mesh:

Year:  2009        PMID: 19544789      PMCID: PMC2832030          DOI: 10.1118/1.3116363

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Aortic valve replacement for aortic stenosis in persons aged 80 years and over.

Authors:  A T Culliford; A C Galloway; S B Colvin; E A Grossi; F G Baumann; R Esposito; G H Ribakove; F C Spencer
Journal:  Am J Cardiol       Date:  1991-06-01       Impact factor: 2.778

Review 2.  Percutaneous valve replacement: current state and future prospects.

Authors:  Georg Lutter; Reza Ardehali; Jochen Cremer; Philipp Bonhoeffer
Journal:  Ann Thorac Surg       Date:  2004-12       Impact factor: 4.330

3.  Robust x-ray tubes for use within magnetic fields of MR scanners.

Authors:  Zhifei Wen; Rebecca Fahrig; Norbert J Pelc
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

4.  Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: a truly hybrid x-ray/MR imaging system.

Authors:  R Fahrig; Z Wen; A Ganguly; G DeCrescenzo; J A Rowlands; G M Stevens; R F Saunders; N J Pelc
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

5.  Percutaneous aortic valve implantation retrograde from the femoral artery.

Authors:  John G Webb; Mann Chandavimol; Christopher R Thompson; Donald R Ricci; Ronald G Carere; Brad I Munt; Christopher E Buller; Sanjeevan Pasupati; Samuel Lichtenstein
Journal:  Circulation       Date:  2006-02-06       Impact factor: 29.690

6.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

7.  Transapical transcatheter aortic valve implantation in humans: initial clinical experience.

Authors:  Samuel V Lichtenstein; Anson Cheung; Jian Ye; Christopher R Thompson; Ronald G Carere; Sanjeevan Pasupati; John G Webb
Journal:  Circulation       Date:  2006-07-31       Impact factor: 29.690

8.  Why do so few older people with aortic stenosis have valve replacement surgery?

Authors:  A R Abdul-Hamid; G P Mulley
Journal:  Age Ageing       Date:  1999-05       Impact factor: 10.668

9.  Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis.

Authors:  Alain Cribier; Hélène Eltchaninoff; Christophe Tron; Fabrice Bauer; Carla Agatiello; Laurent Sebagh; Assaf Bash; Danielle Nusimovici; P Y Litzler; Jean-Paul Bessou; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2004-02-18       Impact factor: 24.094

10.  The natural history of aortic stenosis in adults.

Authors:  M A Chizner; D L Pearle; A C deLeon
Journal:  Am Heart J       Date:  1980-04       Impact factor: 4.749

View more
  5 in total

Review 1.  Navigational Tools for Interventional Radiology and Interventional Oncology Applications.

Authors:  Monzer A Chehab; Waleed Brinjikji; Alexander Copelan; Aradhana M Venkatesan
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

2.  Design optimization of MR-compatible rotating anode x-ray tubes for stable operation.

Authors:  Mihye Shin; Prasheel Lillaney; Waldo Hinshaw; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

3.  Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields.

Authors:  Prasheel Lillaney; Mihye Shin; Waldo Hinshaw; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

4.  Magnetostatic focal spot correction for x-ray tubes operating in strong magnetic fields using iterative optimization.

Authors:  Prasheel Lillaney; Mihye Shin; Steven M Conolly; Rebecca Fahrig
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

5.  Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system.

Authors:  Prasheel Lillaney; Mihye Shin; Waldo Hinshaw; N Robert Bennett; Norbert Pelc; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.