Literature DB >> 23114537

TAVI 2012: state of the art.

Jochen Reinöhl1, Constantin von Zur Mühlen, Martin Moser, Stefan Sorg, Christoph Bode, Manfred Zehender.   

Abstract

The development of "transcatheter aortic valve implantation (TAVI)" is changing the field of cardiovascular medicine rapidly. The basic principle of TAVI is the percutaneous implantation of a bioprosthesis mounted in a metal frame. The prosthesis, which is attached to the tip of the catheter, is positioned in the native aortic valve and expanded. The first successful implantation was made by Alain Cribier in 2002. Several smaller mono- and multicenter studies later confirmed the technical feasibility of this procedure. Its true value as an important, therapeutic alternative to open heart surgery in inoperable and high-risk patients is now confirmed in large multicenter registries and by the prospective, randomized PARTNER trial. Decisive for the future acceptance of the procedure and for a possible expansion of the indication spectrum will be (1) continuous further development of the implantation technique and the prosthesis design, (2) reduction of TAVI-associated complications, (3) confirmation of the initial positive long-term results and (4) confirmation of the promising results in the treatment of surgical prosthesis dysfunctions and of patients with low to intermediate risk.

Entities:  

Mesh:

Year:  2013        PMID: 23114537     DOI: 10.1007/s11239-012-0825-4

Source DB:  PubMed          Journal:  J Thromb Thrombolysis        ISSN: 0929-5305            Impact factor:   2.300


  120 in total

1.  Risk of acute kidney injury after minimally invasive transapical aortic valve implantation in 270 patients.

Authors:  Arnaud Van Linden; Jörg Kempfert; Ardawan J Rastan; David Holzhey; Johannes Blumenstein; Gerhard Schuler; Friedrich W Mohr; Thomas Walther
Journal:  Eur J Cardiothorac Surg       Date:  2010-12-24       Impact factor: 4.191

2.  Successful percutaneous management of left main trunk occlusion during percutaneous aortic valve replacement.

Authors:  Samir R Kapadia; Lars Svensson; E Murat Tuzcu
Journal:  Catheter Cardiovasc Interv       Date:  2009-06-01       Impact factor: 2.692

3.  Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry.

Authors:  Neil E Moat; Peter Ludman; Mark A de Belder; Ben Bridgewater; Andrew D Cunningham; Christopher P Young; Martyn Thomas; Jan Kovac; Tom Spyt; Philip A MacCarthy; Olaf Wendler; David Hildick-Smith; Simon W Davies; Uday Trivedi; Daniel J Blackman; Richard D Levy; Stephen J D Brecker; Andreas Baumbach; Tim Daniel; Huon Gray; Michael J Mullen
Journal:  J Am Coll Cardiol       Date:  2011-10-20       Impact factor: 24.094

4.  First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis.

Authors:  Eberhard Grube; Jean C Laborde; Bernfried Zickmann; Ulrich Gerckens; Thomas Felderhoff; Barthel Sauren; Andreas Bootsveld; Lutz Buellesfeld; Stein Iversen
Journal:  Catheter Cardiovasc Interv       Date:  2005-12       Impact factor: 2.692

5.  Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes.

Authors:  Peter Wenaweser; Thomas Pilgrim; Nadja Roth; Alexander Kadner; Stefan Stortecky; Bindu Kalesan; Fabienne Meuli; Lutz Büllesfeld; Ahmed A Khattab; Christoph Huber; Balthasar Eberle; Gabor Erdös; Bernhard Meier; Peter Jüni; Thierry Carrel; Stephan Windecker
Journal:  Am Heart J       Date:  2011-05-11       Impact factor: 4.749

6.  Effect of concomitant coronary artery disease on procedural and late outcomes of transcatheter aortic valve implantation.

Authors:  Todd M Dewey; David L Brown; Morley A Herbert; Dan Culica; Craig R Smith; Martin B Leon; Lars G Svensson; Murat Tuzcu; John G Webb; Alain Cribier; Michael J Mack
Journal:  Ann Thorac Surg       Date:  2010-03       Impact factor: 4.330

7.  Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging.

Authors:  Alexander Ghanem; Andreas Müller; Claas P Nähle; Justine Kocurek; Nikos Werner; Christoph Hammerstingl; Hans H Schild; Jörg O Schwab; Fritz Mellert; Rolf Fimmers; Georg Nickenig; Daniel Thomas
Journal:  J Am Coll Cardiol       Date:  2010-02-24       Impact factor: 24.094

8.  Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve.

Authors:  Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Iassen Michev; Rüdiger Lange; William N Anderson; Olaf Wendler
Journal:  Circulation       Date:  2010-06-21       Impact factor: 29.690

9.  Outcomes after transcatheter aortic valve implantation with both Edwards-SAPIEN and CoreValve devices in a single center: the Milan experience.

Authors:  Cosmo Godino; Francesco Maisano; Matteo Montorfano; Azeem Latib; Alaide Chieffo; Iassen Michev; Rasha Al-Lamee; Marta Bande; Marco Mussardo; Francesco Arioli; Alfonso Ielasi; Micaela Cioni; Maurizio Taramasso; Irina Arendar; Antonio Grimaldi; Pietro Spagnolo; Alberto Zangrillo; Giovanni La Canna; Ottavio Alfieri; Antonio Colombo
Journal:  JACC Cardiovasc Interv       Date:  2010-11       Impact factor: 11.195

10.  One-year interim follow-up results of the TRAVERCE trial: the initial feasibility study for trans-apical aortic-valve implantation.

Authors:  Thomas Walther; Marie-Theres Kasimir; Mirko Doss; Gerhard Schuler; Paul Simon; Volker Schächinger; Friedrich W Mohr; Gerhard Wimmer-Greinecker
Journal:  Eur J Cardiothorac Surg       Date:  2010-07-15       Impact factor: 4.191

View more
  2 in total

1.  Two-year survival of patients screened for transcatheter aortic valve replacement with potentially malignant incidental findings in initial body computed tomography.

Authors:  Peter Stachon; Klaus Kaier; Simone Milde; Gregor Pache; Stefan Sorg; Matthias Siepe; Constantin von zur Mühlen; Andreas Zirlik; Friedhelm Beyersdorf; Mathias Langer; Manfred Zehender; Christoph Bode; Jochen Reinöhl
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-03-10       Impact factor: 6.875

2.  In-hospital resource utilization in surgical and transcatheter aortic valve replacement.

Authors:  Jochen Reinöhl; Klaus Kaier; Anja Gutmann; Stefan Sorg; Constantin von Zur Mühlen; Matthias Siepe; Hardy Baumbach; Martin Moser; Annette Geibel; Andreas Zirlik; Philipp Blanke; Werner Vach; Friedhelm Beyersdorf; Christoph Bode; Manfred Zehender
Journal:  BMC Cardiovasc Disord       Date:  2015-10-22       Impact factor: 2.298