Literature DB >> 15151967

Effect of multislice scanners on patient dose from routine CT examinations in East Anglia.

S J Yates1, L C Pike, K E Goldstone.   

Abstract

As part of the dose optimization process, the Ionising Radiation (Medical Exposure) Regulations 2000 include requirements relating to the assessment of patient dose, and the setting and subsequent review of diagnostic reference levels. In East Anglia, audits of effective dose in CT have been carried out in 1996, 1999 and 2002. In the 2002 audit, nine of the 14 scanners assessed had been replaced since the previous audit. Eight of the new scanners were multislice scanners, acquiring up to 16 slices in a single rotation. The objective of the 2002 audit was to investigate the effect of the introduction of these multislice scanners on patient doses from routine CT examinations. Exposure parameters were collected for 10 different types of routine CT examination. In excess of 550 sets of patient data were obtained. For each of these, effective doses were calculated using the results of Monte Carlo simulations published by the National Radiological Protection Board. Averaged across all 10 examinations, regional mean effective doses are 34% higher than in 1999. The multislice scanners in the region give, on average, 35% more effective dose than the single-slice scanners. The effect of collimation in multislice scanners makes these effective dose differences most notable for examinations that use narrow slice widths. Further optimization of exposures on multislice scanners has the potential to reduce the differences observed between single-slice and multislice doses. However, when taken in combination with the increased use of CT in many hospitals, the effective dose increases observed are likely to result in a significant increase in the already substantial collective radiation dose from CT.

Entities:  

Mesh:

Year:  2004        PMID: 15151967     DOI: 10.1259/bjr/21927258

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  Dose levels at coronary CT angiography--a comparison of Dual Energy-, Dual Source- and 16-slice CT.

Authors:  J Matthias Kerl; Ralf W Bauer; Tobias B Maurer; Rene Aschenbach; Huedayi Korkusuz; Thomas Lehnert; Simon Deseive; Hanns Ackermann; Thomas J Vogl
Journal:  Eur Radiol       Date:  2010-09-23       Impact factor: 5.315

2.  Impact of the introduction of 16-row MDCT on image quality and patient dose: Phantom study and multi-centre survey.

Authors:  Francis R Verdun; Nicolas Theumann; Pierre-Alexandre Poletti; Daniel Gutierrez; Abbas Aroua; Pierre Schnyder; Jean-François Valley; Salah D Qanadli
Journal:  Eur Radiol       Date:  2006-08-29       Impact factor: 5.315

Review 3.  Adult patient radiation doses from non-cardiac CT examinations: a review of published results.

Authors:  I Pantos; S Thalassinou; S Argentos; N L Kelekis; G Panayiotakis; E P Efstathopoulos
Journal:  Br J Radiol       Date:  2011-01-25       Impact factor: 3.039

4.  Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality.

Authors:  Boris Bodelle; Constanze Fischbach; Christian Booz; Ibrahim Yel; Claudia Frellesen; Moritz Kaup; Martin Beeres; Thomas J Vogl; Jan-Erik Scholtz
Journal:  Pediatr Radiol       Date:  2017-03-28

5.  Patient dose considerations in computed tomography examinations.

Authors:  Ioannis A Tsalafoutas; Georgios V Koukourakis
Journal:  World J Radiol       Date:  2010-07-28

6.  National diagnostic reference level initiative for computed tomography examinations in Kenya.

Authors:  Geoffrey K Korir; Jeska S Wambani; Ian K Korir; Mark A Tries; Patrick K Boen
Journal:  Radiat Prot Dosimetry       Date:  2015-03-19       Impact factor: 0.972

7.  Radiation dose estimates in dual-source computed tomography coronary angiography.

Authors:  Paul Stolzmann; Hans Scheffel; Thomas Schertler; Thomas Frauenfelder; Sebastian Leschka; Lars Husmann; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2007-10-02       Impact factor: 5.315

8.  Knowledge and Associated Factors of Medical Students Regarding Radiation Exposure from Common Diagnostic Imaging Procedures at the University of Gondar, Ethiopia.

Authors:  Dagnachew Eyachew Amare; Henok Dagne
Journal:  Ethiop J Health Sci       Date:  2020-07-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.