[Surface characterization of Al2O3-blasted titanium implants in total hip arthroplasty].

A Schuh1, U Holzwarth, W Kachler, J Göske, G Zeiler.   

Abstract

INTRODUCTION: Shot peening and grit blasting techniques are used in several surface modifications for producing hip endoprostheses. Corund blasting techniques using highly pure Al2O3 particles to create a rough surface of titanium implants in cementless total hip arthroplasty achieve better osteointegration. An increasing number of publications in maxillofacial surgery and orthopedic surgery show that there is a significant contamination on corund-blasted surfaces. The latest research studies reported an effect of contaminant particles on early failure of endoprostheses associated with third body wear. The aim of our work was to evaluate the amount and particle size of Al2O3 on the implant surface. MATERIAL AND
METHOD: The surface of four different geometries (five parts each, ARR titanium acetabular reinforcement ring, anisotropic Vektor cup, Vektor titanium stem and modular MRP Titan stem) were analyzed with respect to Al2O3 particles. Grit blasting was performed with Al2O3 particles, Alodur SWSK, Fa. Treibacher. Field emission scanning electron microscopy (LEO 1525) was used for the detection of the Al2O3 particles at the implant surface with a backscattered electron detector. The particle size distribution as well as the average area of the covered surface was calculated with image analyzing software (analySIS, Soft Imaging System GmbH).
RESULTS: The surface of the anisotropic Vektor cup was contaminated at an average of 41.7+/-4.9%, the Vektor titanium stem at an average of 33.3+/-4.7%, the (MRP) Titan stem at an average of 30.6+/-4.2%, and the ARR titanium acetabular reinforcement ring at an average of 23.2+/-1.6 with Al2O3 particles over the whole surface orientated to the bone. DISCUSSION: The results of this study clearly show that there is contamination of rough titanium surfaces with Al2O3 particles at an unexpectedly high percentage. With respect to third body wear in total hip arthroplasty, further studies are necessary to minimize contamination of roughened surfaces and maintain sufficient roughness for osteointegration.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15150684     DOI: 10.1007/s00132-004-0663-y

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  18 in total

1.  Femoral revision: distal fixation with fluted, tapered grit-blasted stems.

Authors:  Daniel J Berry
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

Review 2.  The biologic effects of implant materials.

Authors:  J O Galante; J Lemons; M Spector; P D Wilson; T M Wright
Journal:  J Orthop Res       Date:  1991-09       Impact factor: 3.494

3.  Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: an experimental study in rabbits.

Authors:  A Piattelli; L Manzon; A Scarano; M Paolantonio; M Piattelli
Journal:  Int J Oral Maxillofac Implants       Date:  1998 Nov-Dec       Impact factor: 2.804

4.  [Results of uncemented revision arthroplasty of the hip with the MRP-stem using an intrafemoral approach with vascularized distal fenestration].

Authors:  A Schuh; G Zeiler; U Holzwarth
Journal:  Z Orthop Ihre Grenzgeb       Date:  2002 Nov-Dec

5.  Biology of grit-blasted titanium alloy implants.

Authors:  V M Goldberg; S Stevenson; J Feighan; D Davy
Journal:  Clin Orthop Relat Res       Date:  1995-10       Impact factor: 4.176

6.  A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies.

Authors:  A Wennerberg; T Albrektsson; B Andersson; J J Krol
Journal:  Clin Oral Implants Res       Date:  1995-03       Impact factor: 5.977

7.  The CLS system. Theoretical concept and results.

Authors:  L Spotorno; S Romagnoli; N Ivaldo; G Grappiolo; E Bibbiani; D J Blaha; T A Guen
Journal:  Acta Orthop Belg       Date:  1993       Impact factor: 0.500

8.  Metal release from plates used in jaw fracture treatment. A pilot study.

Authors:  L E Moberg; A Nordenram; O Kjellman
Journal:  Int J Oral Maxillofac Surg       Date:  1989-10       Impact factor: 2.789

9.  Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study.

Authors:  C Delaunay; F Bonnomet; J North; D Jobard; C Cazeau; J F Kempf
Journal:  J Arthroplasty       Date:  2001-01       Impact factor: 4.757

10.  Contamination of titanium castings by aluminium oxide blasting.

Authors:  B W Darvell; N Samman; W K Luk; R K Clark; H Tideman
Journal:  J Dent       Date:  1995-10       Impact factor: 4.379

View more
  3 in total

1.  Surface modification of titanium implants using bioactive glasses with air abrasion technologies.

Authors:  Garrit Koller; Richard J Cook; Ian D Thompson; Timothy F Watson; Lucy Di Silvio
Journal:  J Mater Sci Mater Med       Date:  2007-06-12       Impact factor: 3.896

Review 2.  Biomaterials in orthopaedics.

Authors:  M Navarro; A Michiardi; O Castaño; J A Planell
Journal:  J R Soc Interface       Date:  2008-10-06       Impact factor: 4.118

3.  A cementless hip system with a new surface for osseous integration.

Authors:  Richard Lass; Alexander Kolb; Gobert Skrbensky; Georg Reinisch; Bernd Kubista; Alexander Giurea; Reinhard Windhager; Rainer Kotz
Journal:  Int Orthop       Date:  2013-10-11       Impact factor: 3.075

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.