Literature DB >> 17562133

Surface modification of titanium implants using bioactive glasses with air abrasion technologies.

Garrit Koller1, Richard J Cook, Ian D Thompson, Timothy F Watson, Lucy Di Silvio.   

Abstract

A growing number of surface treated titanium implants are routinely used in dental and orthopaedic surgery, with a view to enhancing integration capacity with osseous tissue. This study examines the use of bioactive glass 45S5 as an alternative abrasive and osteoproductive surface modification material. Abrasive blasting of commercially pure titanium with bioactive glass 45S5 produced an irregular finish with a surface roughness average (S(a)) of 1.1 microm as determined by white light interferometry, backscattered and secondary electron microscopy. The roughness attained compares favourably with currently used implant designs. Further, Energy Dispersive X-ray Analysis (EDXA) and backscattered electron microscopy demonstrated that bioactive glass was distributed across the titanium surface and retained within fissures and roughened surface features. Being an osteoproductive material, this is advantageous as it is expected that the modified metallic surfaces will acquire osteopromotive properties, and thus be of benefit to the process of implantation in osseous tissue.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17562133     DOI: 10.1007/s10856-007-3137-z

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  29 in total

1.  Antibacterial activity of particulate bioglass against supra- and subgingival bacteria.

Authors:  I Allan; H Newman; M Wilson
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

2.  Differential response of human osteoblast-like cells to commercially pure (cp) titanium grades 1 and 4.

Authors:  M Ahmad; D Gawronski; J Blum; J Goldberg; G Gronowicz
Journal:  J Biomed Mater Res       Date:  1999-07

3.  Analysis of failed commercially pure titanium dental implants: a scanning electron microscopy and energy-dispersive spectrometer x-ray study.

Authors:  Jamil Awad Shibli; Elcio Marcantonio; Susana d'Avila; Antonio Carlos Guastaldi; Elcio Marcantonio
Journal:  J Periodontol       Date:  2005-07       Impact factor: 6.993

4.  Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide.

Authors:  A Wennerberg; T Albrektsson; B Andersson
Journal:  Int J Oral Maxillofac Implants       Date:  1996 Jan-Feb       Impact factor: 2.804

5.  Stability of hydroxyapatite-coatings on titanium oral implants (IMZ). 2 retrieved cases.

Authors:  H Liao; B Fartash; J Li
Journal:  Clin Oral Implants Res       Date:  1997-02       Impact factor: 5.977

6.  An investigation of Bioglass powders: quality assurance test procedure and test criteria.

Authors:  L D Warren; A E Clark; L L Hench
Journal:  J Biomed Mater Res       Date:  1989-08

Review 7.  Osseointegration and its experimental background.

Authors:  P I Brånemark
Journal:  J Prosthet Dent       Date:  1983-09       Impact factor: 3.426

8.  The interface of various glasses and glass ceramics with a bony implantation bed.

Authors:  U Gross; V Strunz
Journal:  J Biomed Mater Res       Date:  1985-03

9.  Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible.

Authors:  D L Cochran; R K Schenk; A Lussi; F L Higginbottom; D Buser
Journal:  J Biomed Mater Res       Date:  1998-04

10.  Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W.

Authors:  T Kokubo; H Kushitani; S Sakka; T Kitsugi; T Yamamuro
Journal:  J Biomed Mater Res       Date:  1990-06
View more
  5 in total

1.  The bio-functional role of calcium in mesoporous silica xerogels on the responses of osteoblasts in vitro.

Authors:  Huanjun Zhou; Jie Wei; Xiaohui Wu; Jianlin Shi; Changsheng Liu; Junfeng Jia; Chenglong Dai; Qi Gan
Journal:  J Mater Sci Mater Med       Date:  2010-04-22       Impact factor: 3.896

Review 2.  A review of the effect of various ions on the properties and the clinical applications of novel bioactive glasses in medicine and dentistry.

Authors:  Saqib Ali; Imran Farooq; Kefi Iqbal
Journal:  Saudi Dent J       Date:  2013-12-15

Review 3.  Application of bioactive glasses in various dental fields.

Authors:  Nazanin Jafari; Mina Seyed Habashi; Alireza Hashemi; Reza Shirazi; Nader Tanideh; Amin Tamadon
Journal:  Biomater Res       Date:  2022-07-06

Review 4.  Nanomedicine applications in orthopedic medicine: state of the art.

Authors:  Mozhdeh Mazaheri; Niloofar Eslahi; Farideh Ordikhani; Elnaz Tamjid; Abdolreza Simchi
Journal:  Int J Nanomedicine       Date:  2015-09-28

5.  Self-assembled monolayers of alendronate on Ti6Al4V alloy surfaces enhance osteogenesis in mesenchymal stem cells.

Authors:  Luis Rojo; Borzo Gharibi; Robert McLister; Brian J Meenan; Sanjukta Deb
Journal:  Sci Rep       Date:  2016-07-29       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.