Literature DB >> 12068426

Femoral revision: distal fixation with fluted, tapered grit-blasted stems.

Daniel J Berry1.   

Abstract

Fluted, tapered grit-blasted titanium stems for revision total hip arthroplasty have been used extensively in Europe and have been reported to provide mostly favorable results. These stems are tapered to gain axial stability and fluted to gain rotational stability in the femoral diaphysis. Grit-blasted titanium provides a surface for bone ongrowth. Such implants can solve certain problems not addressed easily by other standard revision techniques. The clinical durability of modular implants, introduced to make these implants more user-friendly and more versatile, remains to be proved. These implants require special techniques for implantation, particularly when long-stemmed implants are used. Copyright 2002, Elsevier Science (USA).

Entities:  

Mesh:

Year:  2002        PMID: 12068426     DOI: 10.1054/arth.2002.32463

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  [Surface characterization of Al2O3-blasted titanium implants in total hip arthroplasty].

Authors:  A Schuh; U Holzwarth; W Kachler; J Göske; G Zeiler
Journal:  Orthopade       Date:  2004-08       Impact factor: 1.087

2.  Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty.

Authors:  Maik Hoberg; Christian Konrads; Jana Engelien; Dorothee Oschmann; Michael Holder; Matthias Walcher; Maximilian Rudert
Journal:  Int Orthop       Date:  2015-02-18       Impact factor: 3.075

3.  Mid-term Results of Revision Total Hip Arthroplasty Using Modular Cementless Femoral Stems.

Authors:  Hyung-Gyu Jang; Kyung-Jae Lee; Byung-Woo Min; Hee-Uk Ye; Kyung-Hwan Lim
Journal:  Hip Pelvis       Date:  2015-09-30

4.  Subsidence of monoblock and modular titanium fluted tapered stems in revision hip arthroplasty: A retrospective multicentre comparison study.

Authors:  Eoghan Pomeroy; Seán O Flynn; Mihai Grigoras; Terence P Murphy; Alexandra I Stavrakis; Fiachra E Rowan
Journal:  J Clin Orthop Trauma       Date:  2022-09-13

5.  Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs.

Authors:  Nemandra A Sandiford; Donald S Garbuz; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2016-09-26       Impact factor: 4.176

6.  High medium-term survival of Zweymüller SLR-plus stem used in femoral revision.

Authors:  Panagiotis Korovessis; Thomas Repantis
Journal:  Clin Orthop Relat Res       Date:  2009-03-03       Impact factor: 4.176

7.  Differences between proximal bone remodeling in femoral revisions for aseptic loosening and periprosthetic fractures using the Wagner SL stem.

Authors:  Gábor Friebert; Csaba Gombár; András Bozó; Ilona Polyák; Ádám Brzózka; Krisztián Sisák
Journal:  BMC Musculoskelet Disord       Date:  2021-02-17       Impact factor: 2.362

8.  Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem: 5- to 16-year results of 163 cases.

Authors:  Dieter C Wirtz; Sascha Gravius; Rudolf Ascherl; Miguel Thorweihe; Raimund Forst; Ulrich Noeth; Uwe M Maus; Matthias D Wimmer; Günther Zeiler; Moritz C Deml
Journal:  Acta Orthop       Date:  2014-09-01       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.