The dynamic range of digital radiographic systems: dose reduction or risk of overexposure?

W E R Berkhout1, D A Beuger, G C H Sanderink, P F van der Stelt.   

Abstract

OBJECTIVES: To investigate the range of diagnostically acceptable digital radiographs and film as a function of exposure time, as well as the relationship to dose reduction and consequences for dental practice.
METHODS: Five systems for intraoral radiography were used to take a series of radiographs, with increasing exposure times, of five different dry bone specimens. Seven observers evaluated the 25 series of radiographs. The observers had to determine which radiographs of each series were acceptable for dental diagnostics and which radiograph of each series they preferred.
RESULTS: For Ektaspeed Plus film, the exposure time for the preferred radiograph was 0.52 s, with a range of diagnostically acceptable radiographs from 0.23-1.02 s. The preferred radiograph of the solid-state systems required less radiation than film (Sirona, 0.13 s; MPDx 0.35 s). The exposure range of these systems is narrow. In contrast, the exposure range of the phosphor plate systems is very wide. The preferred radiograph of the phosphor plate systems required high exposure (Digora, 1.21 s; Gendex DenOptix, 1.16 s).
CONCLUSIONS: All digital systems require less exposure than film for diagnostically acceptable radiographs, but this is less obvious for preferred radiographs. Solid-state systems alert the dentist when a too long exposure time is used by a lack of image quality; phosphor plate systems, however, produce good quality radiographs even at high exposure times, which may result in an unnecessarily high dose.

Mesh:

Year:  2004        PMID: 15140814     DOI: 10.1259/dmfr/40677472

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  21 in total

1.  Diagnostic accuracy of proximal enamel subsurface demineralization and its relationship with calcium loss and lesion depth.

Authors:  E Onem; B G Baksi; B H Sen; O Sögüt; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

3.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

Review 4.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

5.  Alternative X-ray filters for an intra-oral digital radiographic system.

Authors:  J Stecke; A D Cruz; S M Almeida; F N Bóscolo
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

6.  The effect of delayed scanning of storage phosphor plates on occlusal caries detection.

Authors:  E Sogur; B G Baksi; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

7.  Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality.

Authors:  D P Melo; A Dos Anjos Pontual; S M de Almeida; P S F Campos; M C Alves; G M Tosoni
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

8.  Rating the extent of surface scratches on photostimulable storage phosphor plates in a dental school environment.

Authors:  S M Kalathingal; M K Shrout; C Comer; C Brady
Journal:  Dentomaxillofac Radiol       Date:  2010-03       Impact factor: 2.419

9.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

10.  Evaluation of low-contrast perceptibility in dental restorative materials under the influence of ambient light conditions.

Authors:  A D Cruz; I C Lobo; A L B Lemos; M F Aguiar
Journal:  Dentomaxillofac Radiol       Date:  2015-01-28       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.