Literature DB >> 1513255

Partial RF echo-planar imaging with the FAISE method. II. Contrast equivalence with spin-echo sequences.

P S Melki1, F A Jolesz, R V Mulkern.   

Abstract

The fast acquisition interleaved spin-echo (FAISE) sequence and its dual-echo version (DEFAISE) are partial RF echo-planar methods which utilize a specific phase-encode reordering algorithm to manipulate T2 contrast via an operator-controlled pseudo-echo time, pTE. The repetition time, TR, between successive applications of the Carr-Purcell-Meiboom-Gill (CPMG) echo trains used in FAISE may be reduced to introduce T1 weighting. To quantitatively determine the extent to which FAISE T1 and T2 contrast characteristics agree with spin-echo methods, signal intensities from FAISE acquisitions were compared with signal intensities from equivalent CPMG acquisitions. In phantoms and in human heads, the contrast characteristics of FAISE are found to be highly correlated with that obtained with equivalent CPMG sequences. However, conventional SE sequences generally utilize longer echo spacings than employed with FAISE/CPMG. Thus, echo spacing-dependent mechanisms such as spin-spin coupling and magnetic susceptibility lead to some differences in contrast between conventional SE and FAISE. Finally, FAISE appears to be more sensitive to magnetization transfer effects than conventional SE sequences since more off-resonance irradiation is applied to individual slices during multislice acquisitions.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1513255     DOI: 10.1002/mrm.1910260213

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Contrast enhancement of intracranial lesions: conventional T1-weighted spin-echo versus fast spin-echo MR imaging techniques.

Authors:  T Sugahara; Y Korogi; Y Ge; Y Shigematsu; L Liang; K Yoshizumi; M Kitajima; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  1999-09       Impact factor: 3.825

2.  Enhanced refocusing of fat signals using optimized multipulse echo sequences.

Authors:  Ashley M Stokes; Yesu Feng; Tanya Mitropoulos; Warren S Warren
Journal:  Magn Reson Med       Date:  2012-05-24       Impact factor: 4.668

3.  Human rapid acquisition with relaxation enhancement imaging at 8 T without specific absorption rate violation.

Authors:  A Kangarlu; A M Abduljalil; C Schwarzbauer; D G Norris; P M Robitaille
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

4.  Detection of intracranial hemorrhage with susceptibility-weighted MR sequences.

Authors:  L Liang; Y Korogi; T Sugahara; Y Shigematsu; T Okuda; I Ikushima; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  1999-09       Impact factor: 3.825

5.  Carr-Purcell-Meiboom-Gill imaging of prostate cancer: quantitative T2 values for cancer discrimination.

Authors:  Joseph R Roebuck; Steven J Haker; Dimitris Mitsouras; Frank J Rybicki; Clare M Tempany; Robert V Mulkern
Journal:  Magn Reson Imaging       Date:  2008-09-26       Impact factor: 2.546

6.  Hepatic MR imaging: comparison of RARE derived sequences with conventional sequences for detection and characterization of focal liver lesions.

Authors:  P Reimer; E J Rummeny; M Wissing; G M Bongartz; G Schuierer; P E Peters
Journal:  Abdom Imaging       Date:  1996 Sep-Oct

7.  Fetal MRI: A Technical Update with Educational Aspirations.

Authors:  Ali Gholipour; Judith A Estroff; Carol E Barnewolt; Richard L Robertson; P Ellen Grant; Borjan Gagoski; Simon K Warfield; Onur Afacan; Susan A Connolly; Jeffrey J Neil; Adam Wolfberg; Robert V Mulkern
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2014-11       Impact factor: 0.481

8.  A comparison between fast and conventional spin-echo in the detection of multiple sclerosis lesions.

Authors:  J W Thorpe; S F Halpin; D G MacManus; G J Barker; B E Kendall; D H Miller
Journal:  Neuroradiology       Date:  1994-07       Impact factor: 2.804

9.  Lung Parenchymal Signal Intensity in MRI: A Technical Review with Educational Aspirations Regarding Reversible Versus Irreversible Transverse Relaxation Effects in Common Pulse Sequences.

Authors:  Robert Mulkern; Steven Haker; Hatsuho Mamata; Edward Lee; Dimitrios Mitsouras; Koichi Oshio; Mukund Balasubramanian; Hiroto Hatabu
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2014-03-01       Impact factor: 0.481

10.  Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T.

Authors:  T Allkemper; W Schwindt; D Maintz; W Heindel; B Tombach
Journal:  Eur Radiol       Date:  2004-03-19       Impact factor: 5.315

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.