Literature DB >> 10512245

Contrast enhancement of intracranial lesions: conventional T1-weighted spin-echo versus fast spin-echo MR imaging techniques.

T Sugahara1, Y Korogi, Y Ge, Y Shigematsu, L Liang, K Yoshizumi, M Kitajima, M Takahashi.   

Abstract

BACKGROUND AND
PURPOSE: The T1-weighted fast spin-echo (T1-FSE) MR imaging sequence is not used routinely, since the speed advantage is not as dramatic as it is in T2-weighted imaging. We evaluated the T1-FSE sequence to determine whether this technique can replace the conventional T1-weighted spin-echo (T1-SE) sequence for routine contrast-enhanced imaging.
METHODS: Sixty-nine patients with intracranial enhancing lesions underwent both T1-SE and T1-FSE sequences in a random order after administration of contrast agent. Acquisition time was 55 seconds for the T1-FSE sequence and 2 minutes 38 seconds for the SE sequence. The conspicuity of enhancing lesions, peritumoral edema, and gray-to-white matter contrast as well as motion and flow artifacts were analyzed. Signal-to-noise ratios of enhancing lesions, gray matter, and white matter as well as contrast-to-noise ratios (CNRs) of enhancing lesions, with gray matter with white matter as the standard, were calculated.
RESULTS: The conspicuity of enhancing lesions was better on T1-FSE sequences than on T1-SE sequences, although the difference in the CNRs of enhancing lesions did not reach significance. Images obtained with the T1-FSE sequence showed less flow and motion artifacts than did those obtained with the T1-SE sequence. The conspicuity of peritumoral edema and gray-to-white matter contrast was lower on the T1-FSE images than on the T1-SE images.
CONCLUSION: The T1-FSE sequence reduces imaging time and has the potential to replace the conventional T1-SE sequence for the evaluation of enhancing lesions in the brain when time is a consideration.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10512245      PMCID: PMC7657740     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  22 in total

Review 1.  Factors influencing contrast in fast spin-echo MR imaging.

Authors:  R T Constable; A W Anderson; J Zhong; J C Gore
Journal:  Magn Reson Imaging       Date:  1992       Impact factor: 2.546

2.  Contrast manipulation and artifact assessment of 2D and 3D RARE sequences.

Authors:  R V Mulkern; S T Wong; C Winalski; F A Jolesz
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

3.  Time-dependent changes in image contrast in brain tumors after gadolinium-DTPA.

Authors:  W Schörner; M Laniado; H P Niendorf; C Schubert; R Felix
Journal:  AJNR Am J Neuroradiol       Date:  1986 Nov-Dec       Impact factor: 3.825

4.  Comparing the FAISE method with conventional dual-echo sequences.

Authors:  P S Melki; R V Mulkern; L P Panych; F A Jolesz
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

5.  RARE imaging: a fast imaging method for clinical MR.

Authors:  J Hennig; A Nauerth; H Friedburg
Journal:  Magn Reson Med       Date:  1986-12       Impact factor: 4.668

6.  Improved contrast of enhancing brain lesions on postgadolinium, T1-weighted spin-echo images with use of magnetization transfer.

Authors:  D A Finelli; G C Hurst; R P Gullapali; E M Bellon
Journal:  Radiology       Date:  1994-02       Impact factor: 11.105

7.  Dynamic imaging of intracranial lesions using fast spin-echo imaging: differentiation of brain tumors and treatment effects.

Authors:  J D Hazle; E F Jackson; D F Schomer; N E Leeds
Journal:  J Magn Reson Imaging       Date:  1997 Nov-Dec       Impact factor: 4.813

8.  Single-dose gadolinium with magnetization transfer versus triple-dose gadolinium in the MR detection of multiple sclerosis lesions.

Authors:  J H van Waesberghe; J A Castelijns; W Roser; N Silver; T Yousry; G J Lycklama à Nijeholt; H J Adèr; B M Uitdehaag; E W Radue; C H Polman; L Kappos; D H Miller; F Barkhof
Journal:  AJNR Am J Neuroradiol       Date:  1997-08       Impact factor: 3.825

9.  Comparison of HASTE and segmented-HASTE sequences with a T2-weighted fast spin-echo sequence in the screening evaluation of the brain.

Authors:  T Sugahara; Y Korogi; T Hirai; S Hamatake; I Ikushima; Y Shigematu; M Takahashi
Journal:  AJR Am J Roentgenol       Date:  1997-11       Impact factor: 3.959

10.  Application of magnetization transfer imaging for intracranial lesions of tuberous sclerosis.

Authors:  M G Jeong; T S Chung; C J Coe; T J Jeon; D I Kim; A Y Joo
Journal:  J Comput Assist Tomogr       Date:  1997 Jan-Feb       Impact factor: 1.826

View more
  2 in total

1.  Three-dimensional Gradient-echo is Effective in Suppressing Radiofrequency Shielding by a Titanium Mesh.

Authors:  Yasuo Takatsu; Rei Yoshida; Kenichiro Yamamura; Yuya Yamatani; Tsuyoshi Ueyama; Tetsuya Kimura; Yuriko Nohara; Tomohiro Sahara; Kengo Nishiyama; Tosiaki Miyati
Journal:  Magn Reson Med Sci       Date:  2020-06-26       Impact factor: 2.471

2.  Comparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences.

Authors:  Mahmood Nazarpoor; Masoud Poureisa; Mohammad Hossein Daghighi
Journal:  Iran J Radiol       Date:  2012-12-27       Impact factor: 0.212

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.