Literature DB >> 20965906

Risk of deterministic effects during endovascular aortic stent graft implantation.

D Kuhelj1, U Zdesar, V Jevtic, D Skrk, G Omahen, D Zontar, M Surlan, M Glusic, P Popovic, I J Kocijancic, V Salapura.   

Abstract

Since the 1990s, stent graft implantation for aortic pathology has become an alternative to extensive surgical procedures in some patients. Indeed, many patients with such pathology are now treated endovascularly. Only limited data concerning the risk of a deterministic effect during aortic stent graft implantation are available Accordingly, 179 consecutive patients treated in our institute between October 2002 and July 2008 with endovascular aortic stent grafts were included in this study. Dosimetric data (kerma area product (KAP) and cumulative dose at the interventional reference point (CD(irp))) from radiograph reports were analysed for 172 patients. On a group of 19 patients, GAFCHROMIC XR type dosimetric films were also used to verify the automatic measurements. Readings from the integrated KAP meter were found to be too high and were therefore corrected - KAP to dose area product (DAP) and CD(irp) to entrance skin dose (ESD). Median DAP was 153 Gy cm² (35-700 Gy cm²) and median ESD was 0.44 Gy (0.12-2.73 Gy). Recorded dosimetric quantities were found to be good predictors of the skin dose and highlighted 4 patients (2.3%) who received skin doses that might cause possible deterministic effects. Endovascular stent graft implantation is less invasive than a surgical procedure and is widely used; mid-term results are encouraging. In a small number of patients, deterministic effects can occur even in departments with well-trained staff. Operators should inform the patients of possible skin injury after receiving high doses of ionising radiation and proper support must be available should that occur.

Entities:  

Mesh:

Year:  2010        PMID: 20965906      PMCID: PMC3473737          DOI: 10.1259/bjr/64623458

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  23 in total

Review 1.  Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient.

Authors:  T R Koenig; F A Mettler; L K Wagner
Journal:  AJR Am J Roentgenol       Date:  2001-07       Impact factor: 3.959

Review 2.  Severe skin reactions from interventional fluoroscopy: case report and review of the literature.

Authors:  L K Wagner; M D McNeese; M V Marx; E L Siegel
Journal:  Radiology       Date:  1999-12       Impact factor: 11.105

3.  Technical note: patient doses received during digital subtraction angiography.

Authors:  H R Steele; D H Temperton
Journal:  Br J Radiol       Date:  1993-05       Impact factor: 3.039

Review 4.  Avoidance of radiation injuries from medical interventional procedures.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2000

5.  Direct and indirect measurement of patient radiation exposure during endovascular aortic aneurysm repair.

Authors:  Dustin J Weiss; Iraklis I Pipinos; G Mathew Longo; Thomas G Lynch; Frank J Rutar; Jason M Johanning
Journal:  Ann Vasc Surg       Date:  2008-11       Impact factor: 1.466

6.  Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology.

Authors:  D Bor; T Sancak; T Olgar; Y Elcim; A Adanali; U Sanlidilek; S Akyar
Journal:  Br J Radiol       Date:  2004-04       Impact factor: 3.039

7.  Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial.

Authors:  R M Greenhalgh; L C Brown; G P S Kwong; J T Powell; S G Thompson
Journal:  Lancet       Date:  2004 Sep 4-10       Impact factor: 79.321

8.  Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose.

Authors:  Donald L Miller; Stephen Balter; Patricia E Cole; Hollington T Lu; Beth A Schueler; Michael Geisinger; Alejandro Berenstein; Robin Albert; Jeffrey D Georgia; Patrick T Noonan; John F Cardella; James St George; Eric J Russell; Tim W Malisch; Robert L Vogelzang; George L Miller; Jon Anderson
Journal:  J Vasc Interv Radiol       Date:  2003-06       Impact factor: 3.464

Review 9.  [Radiation-induced skin reactions (except malignant tumors)].

Authors:  Isabelle Carrotte-Lefebvre; Emmanuel Delaporte; Xavier Mirabel; Frédéric Piette
Journal:  Bull Cancer       Date:  2003-04       Impact factor: 1.276

10.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.

Authors:  J C Parodi; J C Palmaz; H D Barone
Journal:  Ann Vasc Surg       Date:  1991-11       Impact factor: 1.466

View more
  1 in total

1.  Slovenian experience from diagnostic angiography to interventional radiology.

Authors:  Dusan Pavcnik
Journal:  Radiol Oncol       Date:  2014-11-05       Impact factor: 2.991

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.