Literature DB >> 16912851

Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration.

Danielle Hernalsteen1, Guy Cosnard, Annie Robert, Cécile Grandin, Alain Vlassenbroek, Thierry Duprez.   

Abstract

Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous "native" 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4x0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality.

Entities:  

Mesh:

Year:  2006        PMID: 16912851     DOI: 10.1007/s00330-006-0360-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  12 in total

1.  Single- versus multi-detector row CT of the brain: quality assessment.

Authors:  T R Jones; R T Kaplan; B Lane; S W Atlas; G D Rubin
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

2.  Multi-detector row CT angiography of the brain at various kilovoltage settings.

Authors:  Birgit B Ertl-Wagner; Ralf-Thorsten Hoffmann; Roland Bruning; Karin Herrmann; Brad Snyder; Jeffrey D Blume; Maximilian F Reiser
Journal:  Radiology       Date:  2004-03-24       Impact factor: 11.105

3.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation.

Authors:  Tom H Mulkens; Patrick Bellinck; Michel Baeyaert; Dirk Ghysen; Xavier Van Dijck; Elvier Mussen; Caroline Venstermans; Jean-Luc Termote
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

4.  Early experience with the EMI scanner for study of the brain.

Authors:  H L Baker; J K Campbell; O W Houser; D F Reese
Journal:  Radiology       Date:  1975-08       Impact factor: 11.105

5.  Multidetector-array CT: once again, technology creates new opportunities.

Authors:  L L Berland; J K Smith
Journal:  Radiology       Date:  1998-11       Impact factor: 11.105

6.  Spiral CT vs incremental CT: is spiral CT superior in imaging of the brain?

Authors:  M L Bahner; W Reith; I Zuna; R Engenhart-Cabillic; G van Kaick
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

7.  Image quality of spiral CT versus conventional CT in routine brain imaging.

Authors:  R Kuntz; M Skalej; A Stefanou
Journal:  Eur J Radiol       Date:  1998-02       Impact factor: 3.528

8.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.

Authors:  W A Kalender; W Seissler; E Klotz; P Vock
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

9.  Comparison of CT and MR in 400 patients with suspected disease of the brain and cervical spinal cord.

Authors:  W G Bradley; V Waluch; R A Yadley; R R Wycoff
Journal:  Radiology       Date:  1984-09       Impact factor: 11.105

10.  Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses.

Authors:  Walter Huda; Kristin A Lieberman; Jack Chang; Marsha L Roskopf
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

View more
  1 in total

1.  Spiral head CT in the evaluation of acute intracranial pathology: a pictorial essay.

Authors:  Aaron Sodickson; Heitor Okanobo; Stephen Ledbetter
Journal:  Emerg Radiol       Date:  2010-10-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.