Literature DB >> 15015948

Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function.

Frits van Kampen1, Marco Cune, Andries van der Bilt, Frits Bosman.   

Abstract

It could be hypothesised that attachments, which provide more retention against vertical and horizontal dislodgement, will be associated with more favourable parameters of oral function. This in vivo study is designed to provide data regarding initial retention force, loss of retention force after 3 months of function and postinsertion maintenance and complications associated with the use of magnet, bar-clip and ball attachments in mandibular overdenture treatment. Eighteen edentulous subjects received two permucosal implants in the inter-foramina region of the mandible, a new denture and three successive suprastructure modalities (magnet-, bar-clip and ball attachments). The retention force of the attachments at baseline and after 3 months was measured in a standardised way. The amount and type of postinsertion maintenance that was related to the attachment were evaluated. No differences in retention force at baseline and after 3 months of loading were observed for all three attachment types. The mean retention forces of magnet attachments, bar-clip attachments and ball attachments were 8.1, 31.3 and 29.7 N respectively. Functional maintenance complications related to the attachments were predominantly observed in 11/36 magnet attachments. Functional problems in the ball attachment group were relatively rare, easily manageable and seen in 4/36 attachments. The bar-clip attachments exhibited no maintenance problems at all.

Mesh:

Substances:

Year:  2003        PMID: 15015948     DOI: 10.1046/j.0905-7161.2003.00961.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  26 in total

1.  Tissue-supported dental implant prosthesis (overdenture): the search for the ideal protocol. A literature review.

Authors:  Domenica Laurito; Luca Lamazza; Michael J Spink; Alberto De Biase
Journal:  Ann Stomatol (Roma)       Date:  2012-05-03

2.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

3.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

4.  Clinical retention force development of double crowns.

Authors:  Stefan Bayer; Helmut Stark; Lina Gölz; Ludger Keilig; Dominik Kraus; Anja Hansen; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2011-03-01       Impact factor: 3.573

5.  New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space.

Authors:  Abdalbseet A Fatalla; Ke Song; Ying-Guang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

6.  The influences of implant angulations in one and two directions on the retentive properties of overdenture attachments: an in vitro study.

Authors:  Parsa Atashrazm; Mohammad Hossein Dashti; Leila Zamani Alavijeh; Samira Azarmaeh; Sayena Mahdizadeh
Journal:  J Indian Prosthodont Soc       Date:  2013-04-12

Review 7.  Do ball-type attachment systems for overdenture result in better patient-satisfaction? A systematic review of randomized crossover clinical trial.

Authors:  Cleber Davi Del Rei Daltro Rosa; Rafaella de Souza Leão; Cátia Maria Fonseca Guerra; Eduardo Piza Pellizzer; Bruno Gustavo da Silva Casado; Sandra Lúcia Dantas de Moraes
Journal:  Saudi Dent J       Date:  2021-03-14

8.  Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient.

Authors:  Seung-Ryong Ha; Sung-Hun Kim; Seung-Il Song; Seong-Tae Hong; Gy-Young Kim
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

9.  Effects of mucosal thickness on the stress distribution and denture stability of mandibular implant-supported overdentures with unsplinted attachments in vitro.

Authors:  Asuka Haruta; Yasuyuki Matsushita; Yoshihiro Tsukiyama; Yoshinori Sawae; Nobuo Sakai; Kiyoshi Koyano
Journal:  J Dent Biomech       Date:  2011-05-26

10.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.