| Literature DB >> 34434031 |
Cleber Davi Del Rei Daltro Rosa1, Rafaella de Souza Leão2, Cátia Maria Fonseca Guerra3, Eduardo Piza Pellizzer1, Bruno Gustavo da Silva Casado2, Sandra Lúcia Dantas de Moraes2.
Abstract
OBJECTIVE: This review is to compare patient-satisfaction with ball-type overdenture attachment systems with others attachment systems.Entities:
Keywords: Cross-over studies; Denture precision attachment; Overdenture; Patient-satisfaction; Prosthodontics; Systematic review
Year: 2021 PMID: 34434031 PMCID: PMC8376671 DOI: 10.1016/j.sdentj.2021.03.002
Source DB: PubMed Journal: Saudi Dent J ISSN: 1013-9052
Fig. 1Search strategy.
Summary of characteristics of included studies.
| Author | Patient (n) | Mean age, years | Number implant for patients | Design of study | Attachment types | Arch | Implant system and dimensions (mm) | Satisfaction Evaluated Methods | Outcomes Results | Conclusion | Follow-up, months | Preference |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 17 | 61.2 | 2 | RCT CROSSOVER | Ball (17) | Maxilla: 0 | Calcitek Corp., Carlsbad, Calif. | Questionnaire | NR | NS | 12 | Ball | |
| 18 | 45.5 | 2 | RCT CROSSOVER | Bar (18) | Maxilla: 0 Mandible: 18 | Frialit-2, Friadent | VAS | Bar = 85.2 Ball = 86.2 Magneto = 60.2 | NS | 9 | Bar | |
| 22 | 64.3 | 2 | RCT CROSSOVER | Ball (16) | Maxilla: 0 | Bra°nemark | VAS | Ball = 97.0 | Ball is better than magneto in the general satisfaction, stability and ability to chew. | 6 | Ball | |
| 30 | 58.9 | 4 | RCT CROSSOVER | Bar 4 implants(27) Bar 2 implants(27) Ball 2 implants(27) | Maxilla: 0 Mandible: 27 | Brånemark, Nobel Biocare | Questionnaire of 40 questions | NR | NS | 36 | Ball | |
| 20 | 62.4 | 2 | RCT CROSSOVER | Ball (19) | Maxila:0 | Camlog, Screw-line, Altatec | VAS | Ball= | NS | 12 | NR | |
| 24 | 73.2 | 2 | RCT CROSSOVER | Ball (24) | Maxila:0 | Straumann implants | VAS | Ball = 93.5 | Ball is better than Locator in retention. | 12 | Ball | |
| 18 | 66.1 | 1 | RCT CROSSOVER | Ball (18) | Maxila:0 | Titamax, CM Cortical, Neodent Implants | VAS | Ball = 85.0 | NS | 6 | Equator |
D = diameter; L = length NS = not significant; NR = not related; VAS = visual analog scale.
Fig. 2The Cochrane scale for bias risk.
Fig. 3Fig. 2. Assessment of the risk of bias in the included studies based on the Cochrane Risk of Bias Tools.
Fig. 4Forest plot: comparison of studies evaluating patient satisfaction.