Literature DB >> 1488880

Short-term effects of proparacaine on human corneal thickness.

P Herse1, A Siu.   

Abstract

.5% proparacaine HCl is commonly used for topical anaesthesia in ultrasound pachometry prior to refractive surgery. This drug is known to alter corneal epithelial adhesion. Does 0.5% proparacaine result in an alteration in corneal thickness due to changes in the corneal epithelium? Corneal thickness was measured by optical pachometry at 30 sec intervals for 15 min under 3 experimental conditions; 1) 2 drops of artificial tears, 2) 1 drop of 0.5% proparacaine, 3) 2 drops of 0.5% proparacaine. Baseline measurements were recorded before each trial. No significant differences were found between the mean corneal thicknesses measured in the baseline, 2 drops of artificial tears and 1 drop of 0.5% proparacaine conditions. The mean corneal thickness in the 2 drops of 0.5% proparacaine condition was significantly greater than those measured in the other conditions. In particular the measured corneal thickness was significantly different from the baseline measurements 1 to 2 min after instillation of the 2 drops of 0.5% proparacaine. Exponential modelling of the corneal edema recovery function demonstrated that recovery to baseline corneal thickness occurred 7 to 8 min following the instillation of 2 drops of 0.5% proparacaine. The data of this study suggest that only 1 drop of 0.5% proparacaine should be used for topical anaesthesia prior to ultrasound pachometry. This recommendation may minimize the possibility of measuring artifactually large corneal thickness estimates, and thus reduce the possibility of corneal microperforation during refractive surgery.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1488880     DOI: 10.1111/j.1755-3768.1992.tb04879.x

Source DB:  PubMed          Journal:  Acta Ophthalmol (Copenh)        ISSN: 0001-639X


  11 in total

1.  Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry.

Authors:  Hanna Y Kim; Donald L Budenz; Pak S Lee; William J Feuer; Keith Barton
Journal:  Am J Ophthalmol       Date:  2007-12-11       Impact factor: 5.258

2.  Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry.

Authors:  Hani S Al-Mezaine; Saleh A Al-Amro; Dustan Kangave; Abdulkareem Sadaawy; Taher A Wehaib; Saleh Al-Obeidan
Journal:  Int Ophthalmol       Date:  2007-09-26       Impact factor: 2.031

3.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

4.  Comparison of Central Corneal Thickness using Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry.

Authors:  Prasanna Venkatesh Ramesh; Kirti Nath Jha; Krishnagopal Srikanth
Journal:  J Clin Diagn Res       Date:  2017-08-01

5.  Eye rubbing-induced changes in intraocular pressure and corneal thickness measured at five locations, in subjects with ocular allergy.

Authors:  Uchechukwu L Osuagwu; Saud A Alanazi
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

6.  Clinical investigation of the effect of topical anesthesia on intraocular pressure.

Authors:  Turki M Almubrad; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2007-09

7.  Central corneal thickness measured by the Orbscan II system, contact ultrasound pachymetry, and the Artemis 2 system.

Authors:  Tania Paul; Mira Lim; Christopher E Starr; Harriet O Lloyd; D Jackson Coleman; Ronald H Silverman
Journal:  J Cataract Refract Surg       Date:  2008-11       Impact factor: 3.351

8.  Comparison of the precision of the Topcon SP-3000P specular microscope and an ultrasound pachymeter.

Authors:  Turki M Almubrad; Uchechukwu L Osuagwu; Ibrahim Alabbadi; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2011-06-24

9.  Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry.

Authors:  Martin Zimmermann; Susanne Pitz; Irene Schmidtmann; Norbert Pfeiffer; Joanna Wasielica-Poslednik
Journal:  PLoS One       Date:  2017-01-09       Impact factor: 3.240

10.  Differences in Central Corneal Thickness between Spectral Domain-Optical Coherence Tomography and Ultrasound Pachymetry in Patients with Dry Eye Disease.

Authors:  Ali Riza Cenk Celebi; G Ertugrul Mirza
Journal:  J Ophthalmol       Date:  2016-06-08       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.