Literature DB >> 14752425

Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves.

Marc Ruel1, Fraser D Rubens, Roy G Masters, Andrew L Pipe, Pierre Bédard, Paul J Hendry, B Khanh Lam, Ian G Burwash, William G Goldstein, Maurice P Brais, Wilbert J Keon, Thierry G Mesana.   

Abstract

BACKGROUND: We examined factors associated with persistent or recurrent congestive heart failure after aortic valve replacement.
METHODS: Patients who underwent aortic valve replacement with contemporary prostheses (n = 1563) were followed up with annual clinical assessment and echocardiography. The effect of demographic, comorbid, and valve-related variables on the composite outcome of New York Heart Association class III or IV symptoms or congestive heart failure death after surgery was evaluated with stratified log-rank tests, Cox proportional hazard models, and logistic regression. Factors associated with all-cause death were also examined. Prediction models were bootstrapped 1000 times.
RESULTS: Total follow-up was 6768 patient-years (mean, 4.3 +/- 3.3 years; range, 60 days to 17.1 years). Freedom from congestive heart failure or congestive heart failure death was 98.6% +/- 0.3%, 88.6% +/- 1.0%, 73.9% +/- 2.3%, and 45.2% +/- 8.5% at 1, 5, 10, and 15 years, respectively. Age, preoperative New York Heart Association class, left ventricular grade, atrial fibrillation, coronary artery disease, smoking, and redo status predicted congestive heart failure after surgery (all P <.05). Larger prosthesis size and effective orifice area, both absolute and indexed for body surface area, were independently associated with freedom from congestive heart failure. Increased transprosthesis gradients were predicted by prosthesis-patient mismatch and were associated with congestive heart failure after surgery. Mismatch defined as an effective orifice area/body surface area of 0.80 cm(2)/m(2) or less was a significant predictor of congestive heart failure events after surgery, but mismatch defined as an effective orifice area/body surface area of 0.85 cm(2)/m(2) or less was not. Small prosthesis size and mismatch were not significantly associated with all-cause mortality.
CONCLUSIONS: These analyses identify independent predictors of congestive heart failure symptoms and congestive heart failure death late after aortic valve replacement and indicate that prosthesis size has a significant effect on this cardiac end point, but not on overall survival after aortic valve replacement.

Entities:  

Mesh:

Year:  2004        PMID: 14752425     DOI: 10.1016/j.jtcvs.2003.07.043

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  19 in total

Review 1.  A 44-year experience of prosthetic heart valve implantation at Niigata University Hospital.

Authors:  Jun-ichi Hayashi
Journal:  J Artif Organs       Date:  2012-04-24       Impact factor: 1.731

Review 2.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

3.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

4.  Small prosthesis size in aortic valve replacement does not affect mortality.

Authors:  Damien J LaPar; Gorav Ailawadi; Castigliano M Bhamidipati; George Stukenborg; Ivan K Crosby; John A Kern; Irving L Kron
Journal:  Ann Thorac Surg       Date:  2011-09       Impact factor: 4.330

5.  Pulmonary hypertension in cardiac surgery.

Authors:  André Denault; Alain Deschamps; Jean-Claude Tardif; Jean Lambert; Louis Perrault
Journal:  Curr Cardiol Rev       Date:  2010-02

6.  Aortic valve replacement for aortic stenosis in the elderly: influence of prosthesis-patient mismatch on late survival and left ventricular mass regression.

Authors:  Yasuyuki Kato; Yasushi Tsutsumi; Takahiro Kawai; Tomoyuki Goto; Yosuke Takahashi; Hirokazu Ohashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-08-13

7.  Patient-prosthesis mismatch after aortic valve replacement in the elderly.

Authors:  Masaaki Ryomoto; Masataka Mitsuno; Mitsuhiro Yamamura; Hiroe Tanaka; Yasuhiko Kobayashi; Shinya Fukui; Noriko Tsujiya; Tetsuya Kajiyama; Yuji Miyamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-07-08

Review 8.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

9.  Pregnancy in women with prosthetic heart valves.

Authors:  P G Pieper; A Balci; A P Van Dijk
Journal:  Neth Heart J       Date:  2008-12       Impact factor: 2.380

10.  Early results of Bentall-type operations during the last 10 years: comparison of mechanical valves and stentless bioprostheses.

Authors:  Koki Nakamura; Tomohiro Asai; Mikiko Murakami; Yosuke Saitoh; Hiroki Yamaguchi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-01
View more